QUICK

TOP

해외표준 상세정보

관심표준 등록 : 표준업데이트 시 알림서비스

제공형태 더보기
  • 표준

    판매

    ISO 22125-2:2019

    Water quality — Technetium-99 — Part 2: Test method using inductively coupled plasma mass spectrometry (ICP-MS)
    • 발행일 : 2019-11-08
    • 발행기관 : ISO
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어]PDF 229,500원

    • [영어]PRINT 229,500원

상세정보

분야 ISO/TC 147/SC 3 : Radioactivity measurements
적용범위

This document specifies a method for the measurement of 99Tc in all types of water by inductively coupled plasma mass spectrometry (ICP-MS).

The method is applicable to test samples of supply/drinking water, rainwater, surface and ground water, as well as cooling water, industrial water, domestic, and industrial wastewater after proper sampling and handling and test sample preparation. A filtration of the test sample is necessary.

The detection limit depends on the sample volume and the instrument used. The method described in this document, using currently available ICP-MS, has a detection limit of approximately 0,2 ng·kg−1 to 0,5 ng·kg−1 (0,1 Bq·kg−1 to 0,3 Bq·kg−1), which is much lower than the WHO criteria for safe consumption of drinking water (100 Bq·l−1)[3]. The method presented in this document is not intended for the determination of ultra-trace amount of 99Tc.

The mass concentration values in this document are expressed by sample mass unit instead of sample volume unit as it is usually the case in similar standards. The reason is that 99Tc is measured in various matrix types such as fresh water or sea water, which have significant differences in density. The mass concentration values can be easily converted to sample volume unit by measuring the sample volume. However, it increases the uncertainty on the mass concentration result.

The method described in this document is applicable in the event of an emergency situation, but not if 99mTc is present at quantities that could cause interference.

The analysis of Tc adsorbed to suspended matter is not covered by this method.

It is the user's responsibility to ensure the validity of this test method for the water samples tested.

국제분류(ICS)코드 17.240 : 방사능 측정
13.060.60 : 수질의 물리적 특성 검사
페이지수 22
Edition 1

이력정보

No. 표준번호 표준명 발행일 상태
1 ISO 22125-2:2019상세보기 Water quality — Technetium-99 — Part 2: Test method using inductively coupled plasma mass spectrometry (ICP-MS) 2019-11-08 표준

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)