    ISO 10993-17:2023

    Biological evaluation of medical devices — Part 17: Toxicological risk assessment of medical device constituents
    • 발행일 : 2023-09-13
    • 발행기관 : ISO
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어]PDF 319,600원

    • [영어]PRINT 319,600원

상세정보

분야 ISO/TC 194 : Biological and clinical evaluation of medical devices
적용범위

This document specifies the process and requirements for the toxicological risk assessment of medical device constituents. The methods and criteria used to assess whether exposure to a constituent is without appreciable harm are also specified. The toxicological risk assessment can be part of the biological evaluation of the final product, as described in ISO 10993-1.

The process described in this document applies to chemical characterization information obtained in line with ISO 10993-18. When a toxicological risk assessment of either the compositional information or analytical chemistry data (e.g. extractable data or leachable data) are required to determine whether the toxicological risks related to the constituents are negligible or tolerable.

The process described in this document is not intended to apply to circumstances where the toxicological risk has been estimated by other means, such as:

    constituents, excluding cohort of concern or excluded chemicals, that are present in or extracted from a medical device at an amount representative of patient exposure below a relevant, toxicologically-based reporting threshold (see applicable requirements in ISO 10993-18:2020, Annex E and ISO/TS 21726);

    a new or changed medical device for which chemical or biological equivalence has been established with an existing biocompatible or clinically established medical device (see applicable requirements in ISO 10993-18:2020, Annex C).

The process described in this document is also not applicable to:

    medical device constituents that do not contact the body (e.g. in vitro diagnostics);

    biological risks associated with physical interactions of the medical device with the body (i.e. application of mechanical forces, energy or surface morphology, etc.), provided that the chemical exposure is not changed;

    active pharmaceutical ingredients of device-drug combination products or biologic components of device-biologic combination products as additional regulatory considerations can apply;

    exposure to a particular constituent that arises from sources other than the device, such as food, water or air.

국제분류(ICS)코드 11.100.20 : 의료 장비의 생물학적 평가
페이지수 65
Edition 2

이력정보

No. 표준번호 표준명 발행일 상태
1 ISO 10993-17:2023상세보기 Biological evaluation of medical devices — Part 17: Toxicological risk assessment of medical device constituents 2023-09-13 표준
2 ISO 10993-17:2002상세보기 Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances 2002-11-27 구판
3 ISO 10993-17:2023/DAmd 1상세보기 Biological evaluation of medical devices — Part 17: Toxicological risk assessment of medical device constituents — Amendment 1 초안

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)