분야 | ISO/TC 121/SC 3 : Respiratory devices and related equipment used for patient care |
---|---|
적용범위 | NOTE 1 There is guidance or rationale for this subclause contained in Clause AA.2. This document applies to the basic safety and essential performance of ventilatory support equipment, as defined in 201.3.302, for ventilatory impairment, as defined in 201.3.300, hereafter also referred to as ME equipment, in combination with its accessories: — intended for use in the home healthcare environment; NOTE 2 In the home healthcare environment, the supply mains driving the ventilatory support equipment is often not reliable. NOTE 3 Such ventilatory support equipment can also be used in professional health care facilities. — intended for use by a lay operator; — intended for use with patients who have ventilatory impairment, the most fragile of these patients, would not likely experience injury with the loss of this artificial ventilation; and — not intended for patients who are dependent on artificial ventilation for their immediate life support. EXAMPLE 1 Patients with mild to moderate chronic obstructive pulmonary disease (COPD). Ventilatory support equipment is not considered to use a physiologic closed-loop control system unless it uses a physiological patient variable to adjust the artificial ventilation therapy settings. This document is also applicable to those accessories intended by their manufacturer to be connected to the breathing system of ventilatory support equipment for ventilatory impairment, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilatory support equipment for ventilatory impairment. EXAMPLE 2 Breathing sets, connectors, water traps, expiratory valve, humidifier, breathing system filter, external electrical power source, distributed alarm system. If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601‑1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1. NOTE 4 Additional information can be found in IEC 60601‑1:2005+AMD1:2012+AMD2:2020, 4.2. NOTE 5 See ISO/TR 21954 for guidance on the selection of the appropriate ventilator for a given patient. This document does not specify the requirements for: — ventilators or accessories for ventilator-dependent patients intended for critical care applications, which are given in ISO 80601‑2‑12; — ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601‑2‑13; — ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601‑2‑84; — ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601‑2‑72; — ventilatory support equipment or accessories intended for ventilatory insufficiency, which are given in ISO 80601‑2‑80; — sleep apnoea therapy ME equipment, which are given in ISO 80601‑2‑70; — high-frequency jet ventilators (HFJVs), which are given in ISO 80601‑2‑87; — high-frequency oscillatory ventilators (HFOVs); — respiratory high flow equipment, which are given in ISO 80601‑2‑90; NOTE 6 Ventilatory support equipment can incorporate high-flow therapy operational mode, but such a mode is only for spontaneously breathing patients. — user-powered resuscitators, which are given in ISO 10651-4; — gas-powered emergency resuscitators, which are given in ISO 10651-5; — oxygen therapy constant flow ME equipment; and — cuirass or “iron-lung” ventilation equipment. |
국제분류(ICS)코드 | 11.040.10 : 마취제. 호흡 및 소생장비 |
페이지수 | 107 |
Edition | 2 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ISO 80601-2-79:2024 | Medical electrical equipment — Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment | 2024-08-28 | 표준 |
2 | ISO 80601-2-79:2018 | Medical electrical equipment — Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment | 2018-07-18 | 구판 |
ISO/DIS 80601-2-67 - Medical electrical equipment — Part 2-67: Particular requirements for basic safety and essential performance of oxygen-conserving equipment 상세보기
ISO/DIS 80601-2-69 - Medical electrical equipment — Part 2-69: Particular requirements for the basic safety and essential performance of oxygen concentrator equipment 상세보기
ISO 80601-2-56:2017 - Medical electrical equipment — Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement 상세보기
ISO 80601-2-61:2017 - Medical electrical equipment — Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment 상세보기
ISO 80601-2-55:2018 - Medical electrical equipment — Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors 상세보기
함께 구입한 상품이 존재하지 않습니다.
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기