    ASTM F3036-13

    Standard Guide for Testing Absorbable Stents
    • 발행일 : 2013-11-01
    • 발행기관 : ASTM
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어]PDF 128,600원

    • [영어]PRINT 128,600원

상세정보

분야 13.02 : 긴급 의료 서비스; 수색 및 구조
적용범위

1.1 This Guide covers select physical and mechanical characterizations of vascular stents with one or more absorbable components. Such absorbable stents (also referred to as vascular scaffolds) are used to provide temporary luminal support of the coronary and peripheral vasculature following interventional revascularization procedures. This Guide covers devices that are fabricated from one or more degradable polymers and/or metals (from this point on referred to as “absorbable”). This Guide provides a framework for evaluating the change in select physical and mechanical characteristics of absorbable stents from manufacture through their intended degradation in vivo. Specific testing recommendations are limited to existing ASTM standards for stent evaluation.

1.2 Recommendations specific to non-absorbable stents with absorbable coatings are not within scope.

1.3 Recommendations specific to testing absorbable stent grafts are not provided here, however this standard has many elements applicable to testing absorbable stent grafts.

1.4 Clinical need dictates that absorbable stents initially possess the same general dimensions and mechanical function as their non-absorbable counterparts. Thus, utilization of already established mechanical stent evaluation methods is possible when absorbable test specimens are previously conditioned under physiologically relevant temperature and humidity. As a result, this standard addresses absorbable-specific testing issues related to the mechanical and physical evaluation of these devices. This standard is limited to providing absorbable-specific testing recommendations for evaluations where an ASTM method for durable (i.e., non-absorbable) stents is already available. Specifically, this standard provides testing recommendations for adapting the elastic recoil (ASTM F2079), securement/dislodgement (ASTM F2394), and three-point bending (ASTM F2606) tests to fully absorbable devices. This guide generally describes specimen conditioning, as appropriate, for absorbable devices, which can range from none to extensive – depending on the measured attribute and relevant clinical exposure conditions, including time in the in-use environment. There are additional stent evaluation methods that are not addressed explicitly in this guide, e.g., chronic durability, that may require absorbable-specific provisions. The user should justify the appropriate testing for the specific polymer and device.

1.4.1 While the primary purpose of this guide is to address absorbable stent-related issues specific to the tests described in Section 1.3, additional testing (e.g., radial strength) will likely also be needed. Thus, aspects of what is presented herein may be applicable to additional relevant device attributes, such as those described in ISO 25539-1 and/or 25539-2.

1.5 This Guide may not be appropriate for all absorbable devices, for example those that possess limited hydrolytic or corrosion susceptibility and degrade in vivo primarily through enzymatic action. The user is cautioned to consider the appropriateness of the standard in view of the particular absorbable device and its potential application.

1.6 This Guide does not address the methods necessary to characterize the chemical degradation of the absorbable stent (e.g., changes in mass, molecular weight, or degradants). However, this type of characterization does represent an important component of the degradation profile and mechanism of the device. These characterizations are addressed in ASTM F1635.

1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

국제분류(ICS)코드 11.040.40 : 외과. 보철술. 교정술용 이식
페이지수 9
Edition 13

이력정보

No. 표준번호 표준명 발행일 상태
1 ASTM F3036-21상세보기 Standard Guide for Testing Absorbable Stents 2021-11-01 표준
2 ASTM F3036-21 REDLINE상세보기 Standard Guide for Testing Absorbable Stents 2021-11-01 표준
3 ASTM F3036-13상세보기 Standard Guide for Testing Absorbable Stents 2013-11-01 구판

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)