해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-

구판
판매
ASTM D877/D877M-13
Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes- 발행일 : 2013-12-01
- 발행기관 : ASTM
상세정보
| 분야 | 10.03 : 전기절연액 및 가스, 전기 보호 설비 |
|---|---|
| 적용범위 | 1.1 This test method describes two procedures, A and B, for determining the electrical breakdown voltage of insulating liquid specimens. The breakdown test uses ac voltage in the power-frequency range from 45 to 65 Hz. 1.2 This test method is used to judge if the disk electrode breakdown voltage requirements are met for insulating liquids, as delivered from the manufacturer, that have never been filtered or dried. See Specification D3487, Specification D4652, Specification D6871 and Guide D5222 for the minimum specified electrical breakdown. This test method should be used as recommended by professional organization standards such as IEEE C57.106. 1.3 Limitations of the Procedures: 1.3.1 The sensitivity of this test method to the general population of contaminants present in a liquid sample decreases as applied test voltages used in this test method become greater than approximately 25 kV rms. 1.3.2 If the concentration of water in the sample at room temperature is less than 60 % of saturation, the sensitivity of this test method to the presence of water is decreased. For further information refer to RR:D27-1006.2 1.3.3 The suitability for this test method has not been determined for a liquid's viscosity higher than 900 cSt at 40°C. 1.4 Procedure Applications 1.4.1 Procedure A: 1.4.1.1 Procedure A is used to determine the breakdown voltage of liquids in which any insoluble breakdown products easily settle during the interval between the required repeated breakdown tests. These liquids include petroleum oils, hydrocarbons, natural and synthetic esters, and askarels (PCB) used as insulating and cooling liquids in transformers, cables, and similar apparatus. 1.4.1.2 Procedure A may be used to obtain the dielectric breakdown of silicone fluid as specified in Test Methods D2225, provided the discharge energy into the sample is less than 20 mJ (milli joule) per breakdown for five consecutive breakdowns. 1.4.2 Procedure B: 1.4.2.1 This procedure is used to determine the breakdown voltage of liquids in which any insoluble breakdown products do not completely settle from the space between the disks during the 1–min interval required in Procedure A. Procedure B, modified in accordance with Section 17 of Test Methods D2225, is acceptable for testing silicone dielectric liquids if the requirements of 1.4.1.2 can not be achieved. 1.4.2.2 Procedure B should also be applied for the determination of the breakdown voltage of liquid samples containing insoluble materials that settle from the specimen during testing. These may include samples taken from circuit breakers, load tap changers, and other liquids heavily contaminated with insoluble particulate material. These examples represent samples that may have large differences between replicate tests. The use of Procedure B will result in a more accurate value of breakdown voltage when testing such liquids. 1.4.2.3 Use Procedure B to establish the breakdown voltage of an insulating liquid where an ASTM specification does not exist or when developing a value for an ASTM guide or standard. Procedure A may be used once the single operator precision of 13.1 has been demonstrated. 1.5 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
| 국제분류(ICS)코드 | 29.040.10 : 자기재 |
| 페이지수 | 6 |
| Edition | 13 |
이력정보
| No. | 표준번호 | 표준명 | 발행일 | 상태 |
|---|---|---|---|---|
| 1 | ASTM D877/D877M-19상세보기 | Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes | 2019-12-01 | 구판 |
| 2 | ASTM D877/D877M-19e1상세보기 | Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes | 2019-12-01 | 표준 |
| 3 | ASTM D877/D877M-19상세보기 | Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes | 2019-12-01 | 구판 |
| 4 | ASTM D877/D877M-19e1상세보기 | Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes | 2019-12-01 | 표준 |
| 5 | ASTM D877/D877M-13상세보기 | Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes | 2013-12-01 | 구판 |
| 6 | ASTM D877/D877M-13상세보기 | Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes | 2013-12-01 | 구판 |
관련상품
- 관련상품이 존재하지 않습니다.
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO/TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO/TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)PDF+PRINT :
직접 파일 다운로드 및 인쇄본 우편발송(2~3일 소요)보안PDF+PRINT :
직접 파일 다운로드 및 인쇄본 우편발송(2~3일 소요)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능ASME PBVC Plus :
인쇄본 우편발송 및 온라인 구독(1User용, 2년)