    ASTM F3208-20

    Standard Guide for Selecting Test Soils for Validation of Cleaning Methods for Reusable Medical Devices
    • 발행일 : 2020-07-15
    • 발행기관 : ASTM
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어]PDF 109,400원

    • [영어]PRINT 109,400원

상세정보

분야 13.02 : 긴급 의료 서비스; 수색 및 구조
적용범위

1.1 This guide describes methods for selecting test soils for cleaning validations based upon the characteristics of the soil, the physical characteristics of the device, and the clinical use of the device.

1.2 This guide describes the preparation and use of some test soils for the validation of cleaning instructions for reusable medical devices.

1.3 Reusable medical devices such as endoscopes, arthroscopic shavers, surgical instruments, and suction tubes are exposed to biological soils during clinical use. Preparation of these devices for reuse requires cleaning and disinfection and/or sterilization as applicable. Adequate cleaning is the first step in a process intended to prevent contaminant transfer to the next patient and medical practitioner. The soils, if inadequately removed, can interfere with disinfection and sterilization processes, as well as performance of the device. Acceptance criteria are based either on a visual assessment or quantitatively specified marker(s) endpoint(s) of the soil or both (ISO/TS 15883-5, Section 1). Endpoints after cleaning should be based upon possible interference with disinfection/sterilization, risk to the patient or health care worker from the contaminant during further handling, and endpoints for cleaning established in the scientific literature.

1.4 The test soils are designed to simulate the contaminants that medical devices are likely to come in contact with during clinical use. The test soils discussed in this guide are a mixture of constituents that simulate what is commonly found in human secretions, blood, tissue, and bone fragments/shavings as well as non-patient derived soil (e.g., bone cement, lubricants, and dyes) during clinical procedures. The test soils also simulate the physical parameters (e.g., viscosity, adhesion) of clinical material to which the medical devices will be exposed.

1.5 Exclusion: 

1.5.1 This guide does not include methods to validate cleaning processes to remove residues from manufacturing

1.5.2 This guide does not describe the soil/inoculum used for validation of disinfection or sterilization instructions. Disinfection or sterilization validation requires separate testing that is independent of cleaning validation studies.

1.5.3 Test soils described are not intended for use by health care facilities to verify the effectiveness of their cleaning process.

1.5.4 The test soil recipes are not intended to encompass every biological residue with which a medical device is likely to come into contact.

1.6 Test soil formulations not described in this guide may be clinically relevant and may be more appropriate for simulated-use testing depending upon the clinical use of the medical device. The burden is upon the medical device manufacturer to determine and justify scientifically the selection of test soil(s).

1.7 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

국제분류(ICS)코드 11.080.01 : 일반 살균 및 소독
11.040.01 : 일반 의료장비
페이지수 9
Edition 20

이력정보

No. 표준번호 표준명 발행일 상태
1 ASTM F3208-20상세보기 Standard Guide for Selecting Test Soils for Validation of Cleaning Methods for Reusable Medical Devices 2020-07-15 표준
2 ASTM F3208-20 REDLINE상세보기 Standard Guide for Selecting Test Soils for Validation of Cleaning Methods for Reusable Medical Devices 2020-07-15 표준
3 ASTM F3208-19상세보기 Standard Guide for Selecting Test Soils for Validation of Cleaning Methods for Reusable Medical Devices 2019-11-15 구판
4 ASTM F3208-19 REDLINE상세보기 Standard Guide for Selecting Test Soils for Validation of Cleaning Methods for Reusable Medical Devices 2019-11-15 구판
5 ASTM F3208-18 REDLINE상세보기 Standard Guide for Selecting Test Soils for Validation of Cleaning Methods for Reusable Medical Devices 2018-10-01 구판
6 ASTM F3208-18상세보기 Standard Guide for Selecting Test Soils for Validation of Cleaning Methods for Reusable Medical Devices 2018-10-01 구판
7 ASTM F3208-17상세보기 Standard Guide for Selecting Test Soils for Validation of Cleaning Methods for Reusable Medical Devices 2017-01-15 구판

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)