해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-

표준
판매
ASTM F1877-24
Standard Practice for Characterization of Particles- 발행일 : 2024-10-01
- 발행기관 : ASTM
상세정보
| 분야 | 13.01 : 의료기, 외과용 도구 및 장비 |
|---|---|
| 적용범위 | 1.1?This practice covers a series of recommendations, generally applicable to all medical devices, for characterization of the morphology, shape, size, and size distribution of particles. The methods utilized include sieves, optical, scanning electron microscopy (SEM), transmission electron microscopy (TEM), and electrooptical. 1.2?While characterizing the quantity or number of particles shed from medical devices is important, this is not covered within the scope of the current document. AAMI TIR 42 and USP <788> provide guidelines for determination of particle quantities in various size ranges. 1.3?These methods are appropriate for particles produced by a number of different methods. These methods can include simulated use approaches such as in vitro wear test machines (Test Method F732), total joint simulation systems (Guides F1714 and F1715), abrasion testing, and vascular durability testing (Guide F2942). Other methods for producing particles such as shatter boxes or pulverizers, as well as commercially available particles, and particles harvested from tissues in animal or clinical studies can be used. 1.4?Except for chemical composition, this standard does not address sample preparation procedures and/or test systems that can be affected by chemical properties (for example, solubility, miscibility). While this standard does not provide detailed recommendations regarding assessment of chemical properties of particles, these should be considered. 1.5?The particles may be metallic, polymeric, or ceramic and are released from medical device materials either acutely or chronically (for example, due to wear). 1.6?The digestion procedures to be used and issues of sterilization of retrieved particles are not the subject of this practice. 1.7?A classification scheme for description of particle morphology is included in Appendix X3. 1.8?When nanoparticles (that is, having at least one dimension less than 100 nm) are known to be present or are expected, other characterization methods may be needed. For information regarding nanoparticle characterization, refer to standards that address nanoparticles (for example, ISO 21363, ISO/TR 10993-22, ISO/TR 16196). 1.9?This standard does not address ions released from medical devices. 1.10?The values stated in SI units, including units officially accepted for use with SI, are to be regarded as standard. No other systems of measurement are included in this standard. 1.11?As a precautionary safety measure for handling test samples during particle characterization analyses, removed particles from implant tissues should be sterilized or minimally disinfected by an appropriate means that does not adversely affect these particles. 1.12?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.13?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
| 국제분류(ICS)코드 | 19.120 : 입도 분석. 체가름 |
| 페이지수 | 16 |
| Edition | 24 |
이력정보
| No. | 표준번호 | 표준명 | 발행일 | 상태 |
|---|---|---|---|---|
| 1 | ASTM F1877-24상세보기 | Standard Practice for Characterization of Particles | 2024-10-01 | 표준 |
| 2 | ASTM F1877-16상세보기 | Standard Practice for Characterization of Particles | 2016-10-01 | 구판 |
| 3 | ASTM F1877-05(2010)상세보기 | Standard Practice for Characterization of Particles | 2010-06-01 | 구판 |
| 4 | ASTM F1877-05상세보기 | Standard Practice for Characterization of Particles | 2005-11-01 | 구판 |
| 5 | ASTM F1877-05e1상세보기 | Standard Practice for Characterization of Particles | 2005-11-01 | 구판 |
| 6 | ASTM F1877-98(2003)e1상세보기 | Standard Practice for Characterization of Particles | 2003-04-10 | 구판 |
| 7 | ASTM F1877-98상세보기 | Standard Practice for Characterization of Particles | 1998-04-10 | 구판 |
관련상품
- 관련상품이 존재하지 않습니다.
다른 사람이 함께 구입한 상품
- ASTM E466-21 - Standard Practice for Conducting Force Controlled Constant Amplitude Axial Fatigue Tests of Metallic Materials
- SAE AMS7008 - Nickel Alloy, Corrosion and Heat-Resistant, Powder for Additive Manufacturing, 47.5Ni - 22Cr - 1.5Co - 9.0Mo - 0.60W - 18.5Fe
- ASTM B212-25 - Standard Test Method for Apparent Density of Free-Flowing Metal Powders Using the Hall Flowmeter Funnel
- ASTM E3-11(2025) - Standard Guide for Preparation of Metallographic Specimens
- ASTM E1479-24 - Standard Practice for Describing and Specifying Inductively Coupled Plasma Atomic Emission Spectrometers
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO/TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO/TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)PDF+PRINT :
직접 파일 다운로드 및 인쇄본 우편발송(2~3일 소요)보안PDF+PRINT :
직접 파일 다운로드 및 인쇄본 우편발송(2~3일 소요)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능ASME PBVC Plus :
인쇄본 우편발송 및 온라인 구독(1User용, 2년)