해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
표준
판매
ASTM F1977-22 REDLINE
Standard Test Method for Determining Initial, Fractional, Filtration Efficiency of a Vacuum Cleaner System- 발행일 : 2022-01-01
- 발행기관 : ASTM
-
레드라인이란?
최신표준과 직전 구판표준의 변경내용을 포함하고 있는 버전. 구입 시 최신표준과 레드라인 두 개 파일을 제공합니다.
상세정보
분야 | |
---|---|
적용범위 | 1.1?This test method may be used to determine the initial, fractional, filtration efficiency of household and commercial canister (tank-type), stick, hand-held, upright, and utility vacuum cleaner systems. 1.1.1?Water-filtration vacuum cleaners which do not utilize a replaceable dry media filter located between the water-based filter and cleaning air exhaust are not included in this test method. It has been determined that the exhaust of these vacuum cleaners is not compatible with the specified discrete particle counter (DPC) procedure. 1.2?The initial, fractional, filtration efficiencies of the entire vacuum cleaner system, at six discrete particle sizes (0.3, 0.5, 0.7, 1.0, 2.0, and >3 μm), is derived by counting upstream challenge particles and the constituent of downstream particles while the vacuum cleaner system is being operated in a stationary test condition. 1.3?The vacuum cleaner system is tested either at the floor nozzle, the end of the hose (handle), or at the vacuum cleaner inlet (for handheld products) at the normal airflow rate. 1.4?The vacuum cleaner system is tested with a new filter(s) installed, and with no preliminary dust loading. The fractional efficiencies determined by this test method shall be considered initial system filtration efficiencies. 1.5?Neutralized potassium chloride (KCl) is used as the challenge media in this test method. 1.6?One or two particle counters may be used to satisfy the requirements of this test method. If using one counter, flow control is required to switch between sampling the upstream and downstream air sampling probes. 1.7?To efficiently utilize this test method, automated test equipment and computer data acquisition is recommended. 1.8?Different sampling parameters, flow rates, and so forth, for the specific applications of the equipment and test procedure may provide equivalent results. It is beyond the scope of this test method to define those various possibilities. 1.9?This test method is limited to the test apparatus, or its equivalent, as described in this document. 1.10?This test method is not intended or designed to provide any measure of the health effects or medical aspects of vacuum cleaning. 1.11?This test method is not intended or designed to determine the integrity of HEPA filtration assemblies used in vacuum cleaner systems employed in nuclear and defense facilities. 1.12?The inch-pound system of units is used in this test method, except for the common usage of the micrometer, μm, for the description of particle size which is a SI unit. 1.13?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.14?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
국제분류(ICS)코드 | |
페이지수 | 18 |
Edition | 22 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ASTM F1977-22상세보기 | Standard Test Method for Determining Initial, Fractional, Filtration Efficiency of a Vacuum Cleaner System | 2022-01-01 | 표준 |
2 | ASTM F1977-22 REDLINE상세보기 | Standard Test Method for Determining Initial, Fractional, Filtration Efficiency of a Vacuum Cleaner System | 2022-01-01 | 표준 |
3 | ASTM F1977-04(2017)상세보기 | Standard Test Method for Determining Initial, Fractional, Filtration Efficiency of a Vacuum Cleaner System | 2017-03-01 | 구판 |
4 | ASTM F1977-04(2010)상세보기 | Standard Test Method for Determining Initial, Fractional, Filtration Efficiency of a Vacuum Cleaner System | 2010-04-01 | 구판 |
5 | ASTM F1977-04상세보기 | Standard Test Method for Determining Initial, Fractional, Filtration Efficiency of a Vacuum Cleaner System | 2004-03-01 | 구판 |
6 | ASTM F1977-99상세보기 | Standard Test Method for Determining Initial, Fractional, Filtration Efficiency of a Vacuum Cleaner System | 1999-05-10 | 구판 |
관련상품
- 관련상품이 존재하지 않습니다.
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)