QUICK

TOP

해외표준 상세정보

관심표준 등록 : 표준업데이트 시 알림서비스

제공형태 더보기
  • KS

    표준

    판매

    ASTM F748-25 REDLINE

    Standard Practice for Selecting Biological Test Methods for Materials and Devices
    • 발행일 : 2025-02-15
    • 발행기관 : ASTM
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어]PDF(레드라인) 131,600원

    • [영어]PRINT(레드라인) 131,600원

  • 레드라인이란?

    최신표준과 직전 구판표준의 변경내용을 포함하고 있는 버전. 구입 시 최신표준과 레드라인 두 개 파일을 제공합니다.

상세정보

분야
적용범위

1.1?This practice describes biological test methods (as listed in 2.1) which may be used in support of a biological evaluation of materials and medical devices according to end-use applications. Biological evaluation is a component of a broader safety evaluation and is conducted within an ISO 14971 risk management framework. ISO 10993-1 sets out the general principles and requirements for such an evaluation. A biological evaluation conducted according to ISO 10993-1 requires a consideration of the composition of the medical device and the review of pre-existing information pertinent to biological risks. In many cases this pre-existing information will be sufficient to establish safety without a need for additional testing. Only where existing information is insufficient it may be necessary to conduct further testing (see ISO 10993-1). The purpose of this document is to provide guidance on available and applicable test methods to support such testing activities if they are required.

1.2?The reader is cautioned that the area of biocompatibility testing is a rapidly evolving field, and improved methods are becoming available continuously, so this practice is a guideline. A thorough knowledge of current techniques and research is critical to a complete evaluation of new materials and medical devices.

1.3?Biological evaluation of materials and medical devices for human application is discussed. Tests include those performed on materials, final finished medical devices, and extracts. The current state of the art is included for all test procedures described.

1.4?The biocompatibility of materials used in single or multicomponent medical devices for human use depends to a large degree on the particular nature and duration of tissue contact during intended use. It is not possible to specify a set of test methods which will be necessary and sufficient to establish biocompatibility for all materials and applications. Because biological reactions caused by a material or a medical device can have different implications or raise different safety concerns depending on the type and duration of tissue contact of the medical device, each application must be evaluated for biocompatibility and any associated testing on its own merit.

1.5?The evaluation of tissue-engineered medical products (TEMPs) may, in some cases, involve different or additional testing beyond that conducted on non-TEMPs-based materials and medical devices. Where appropriate, these differences are discussed in this practice and additional tests described. For additional information, see reference standards published under the jurisdiction of the applicable TEMPs Subcommittees of F04.

1.6?The ethical use of research animals places the obligation on the individual investigator to determine the most efficient methods for performing the necessary testing without undue use of animals. Where adequate prior data exists to substantiate certain types of safety information, these guidelines should not be interpreted to mean that testing should be unnecessarily repeated. Refer to ISO 10993-2 for additional information.

1.7?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.8?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

국제분류(ICS)코드
페이지수 9
Edition 25

이력정보

No. 표준번호 표준명 발행일 상태
1 ASTM F748-25상세보기 Standard Practice for Selecting Biological Test Methods for Materials and Devices 2025-02-15 표준
2 ASTM F748-25 REDLINE상세보기 Standard Practice for Selecting Biological Test Methods for Materials and Devices 2025-02-15 표준
3 ASTM F748-16상세보기 Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices 2016-04-01 구판
4 ASTM F748-16 REDLINE상세보기 Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices 2016-04-01 구판
5 ASTM F748-06(2010)상세보기 Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices 2010-06-01 구판
6 ASTM F748-06상세보기 Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices 2006-12-01 구판
7 ASTM F748-04상세보기 Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices 2004-05-01 구판
8 ASTM F748-98상세보기 Standard Practice for Selecting Generic Biological Test Methods for Materials and Devices 1998-08-10 구판

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)