해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
폐지
판매
CAN/CSA-ISO 11607-2:16
Packaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing and assembly processes (Adopted ISO 11607-2:2006, first edition, 2006-04-15, including amendment 1:2014)- 발행일 : 2016-01-01
- 발행기관 : CSA
상세정보
분야 | |
---|---|
적용범위 | Preface ? This is the first edition of CAN/CSA-ISO 11607-2, Packaging for terminally sterilized medical devices - Part 2: Validation requirements for forming, sealing and assembly processes, which is an adoption without modification of the identically titled ISO (International Organization for Standardization) Standard 11607-2 (first edition, 2006-04-15), including Amendment 1:2014.? For brevity, this Standard will be referred to as "CAN/CSA-ISO 11607-2" throughout.? This Standard is one of two Standards developed by the Canadian Mirror Committee to ISO/TC 198 that are being adopted by CSA Group under the series Packaging for terminally sterilized medical devices, which consists of the following:? a) ISO 11607-1, Part 1: Requirements for materials, sterile barrier systems and packaging systems; and? b) ISO 11607-2, Part 2: Validation requirements for forming, sealing and assembly processes.? Scope This part of ISO 11607 specifies the requirements for development and validation of processes for packaging medical devices that are terminally sterilized. These processes include forming, sealing, and assembly of preformed sterile barrier systems, sterile barrier systems and packaging systems.? This part of ISO 11607 is applicable to industry, to health care facilities, and wherever medical devices are packaged and sterilized.? This part of ISO 11607 does not cover all requirements for packaging medical devices that are manufactured aseptically. Additional requirements may also be necessary for drug/device combinations. |
국제분류(ICS)코드 | |
페이지수 | 70 |
Edition |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ISO 11607-2:2019/Amd 1:2023상세보기 | Packaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing and assembly processes — Amendment 1: Application of risk management | 2023-09-13 | 표준 |
2 | CSA ISO 11607-2:21상세보기 | Packaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing and assembly processes (Adopted ISO 11607-2:2019, second edition, 2019-02) | 2021-01-01 | 표준 |
3 | ISO 11607-2:2019상세보기 | Packaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing and assembly processes | 2019-01-31 | 표준 |
4 | CAN/CSA-ISO 11607-2:16상세보기 | Packaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing and assembly processes (Adopted ISO 11607-2:2006, first edition, 2006-04-15, including amendment 1:2014) | 2016-01-01 | 폐지 |
5 | ISO 11607-2:2006/Amd 1:2014상세보기 | Packaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing and assembly processes — Amendment 1 | 2014-07-07 | 구판 |
6 | ISO 11607-2:2006상세보기 | Packaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing and assembly processes | 2006-04-07 | 구판 |
관련상품
- ISO 11607-2:2019 - Packaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing and assembly processes
- ISO 11607-1:2019 - Packaging for terminally sterilized medical devices — Part 1: Requirements for materials, sterile barrier systems and packaging systems
- CSA ISO 11607-2:21 - Packaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing and assembly processes (Adopted ISO 11607-2:2019, second edition, 2019-02)
- CSA ISO 11607-1:21 - Packaging for terminally sterilized medical devices — Part 1: Requirements for materials, sterile barrier systems and packaging systems (Adopted ISO 11607-1:2019, second edition, 2019-02)
- ISO 11607-1:2019/Amd 1:2023 - Packaging for terminally sterilized medical devices — Part 1: Requirements for materials, sterile barrier systems and packaging systems — Amendment 1: Application of risk management
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)