해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
표준
판매
CAN/CSA-E60730-2-6:17 (R2022)
Automatic electrical controls — Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements (Adopted IEC 60730-2-6:2015, third edition, 2015-04, with Canadian deviations)- 발행일 : 2017-01-01
- 발행기관 : CSA
상세정보
분야 | 11 : LG Electronics |
---|---|
적용범위 | Preface This is the second edition of CAN/CSA-E60730-2-6, Automatic electrical controls ? Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60730-2-6 (third edition, 2015-04). It supersedes the previous edition published in 1994 as CAN/CSA-E730-2-6 (adopted IEC 730-2-6:1991). At the time of publication, IEC 60730-2-6:2015 is available from IEC in English only. CSA Group will publish the French version when it becomes available from IEC.? For brevity, this Standard will be referred to as "CAN/CSA-E60730-2-6" throughout.? This Standard is intended to be used in conjunction with CAN/CSA-E60730-1:15, Automatic electrical controls ? Part 1: General requirements (adopted IEC 60730-1:2013, with Canadian deviations).? Scope and normative references This clause of Part 1 is applicable except as follows:? 1.1 Scope ? Replacement:? This part of IEC 60730 applies to automatic electrical pressure sensing controls with a minimum gauge pressure rating of ?60 kPa and a maximum gauge pressure rating of 4,2 MPa, for use in, on or in association with, equipment. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof.? NOTE Throughout this standard, the word "equipment" includes "appliances" and "control system".? This standard is also applicable to individual pressure sensing controls utilized as part of a control system or pressure sensing controls which are mechanically integral with multifunctional controls having non-electrical outputs.? Automatic electrical pressure sensing controls for equipment used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.? This standard does not apply to pressure sensing controls intended exclusively for industrial process applications unless explicitly mentioned in the relevant equipment standard.? 1.1.1 Replacement:? This standard applies to inherent safety, operating values, operating sequences where such are associated with equipment protection, and to the testing of automatic electrical pressure sensing controls used in, on or in association with equipment.? This standard is also applicable to the functional safety of low complexity safety related pressure sensing controls and systems.? This standard is also applicable to pressure sensing controls for appliances within the scope of IEC 60335-1.? See also Annex J.? 1.1.2 Addition:? This standard applies to automatic electrical controls, mechanically or electrically operated, responsive to or controlling a pressure or vacuum.? 1.1.3 Not applicable.? 1.1.4 Replacement:? This standard applies to manual controls when such are electrically and/or mechanically integral with pressure sensing controls.? NOTE Requirements for manual switches not forming part of an automatic control are contained in IEC 61058-1.? 1.1.5? Replacement:? This standard applies to a.c. or d.c. powered pressure sensing controls with a rated voltage not exceeding 690 V a.c. or 600 V d.c.? 1.1.6? Replacement:? This standard does not take into account the response value of an automatic action of a pressure sensing control, if such a response value is dependent upon the method of mounting it in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate equipment standard or as determined by the manufacturer shall apply.? 1.1.7? Replacement:? This standard applies also to pressure sensing controls incorporating electronic devices, requirements for which are contained in Annex H.? This standard applies also to pressure sensing controls using NTC or PTC thermistors, requirements for which are contained in Annex J.? Additional sub clauses:? 1.1.101 This standard contains requirements for electrical features of pressure sensing controls and requirements for mechanical features that affect their intended operation.? NOTE Subclause 18.101, as it pertains to gas and/or oil controls, is under consideration pending review or revision of ISO 22967, ISO 22968 and ISO 23550 series, if applicable.? 1.1.102 In general, these pressure sensing controls are integrated or incorporated with the equipment or are intended to be integrated in, or on the equipment. This standard also covers these controls when they are independently mounted. In-line cord controls are not covered by this standard. ? |
국제분류(ICS)코드 | |
페이지수 | 48 |
Edition |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | CAN/CSA-E60730-2-6:17 (R2022)상세보기 | Automatic electrical controls — Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements (Adopted IEC 60730-2-6:2015, third edition, 2015-04, with Canadian deviations) | 2017-01-01 | 표준 |
관련상품
- CAN/CSA-E60730-2-10:13 (R2023) - Automatic electrical controls for household and similar use - Part 2-10: Particular requirements for motor-starting relays (Adopted IEC 60730-2- 10:2006, second edition, 2006-10, with Canadian deviations) | Dispositifs de commande électrique automatiques
- CSA E60730-1:15 (R2020) - Automatic electrical controls – Part 1: General requirements (Adopted IEC 60730-1:2013, fifth edition, 2013-11, with Canadian deviations) | Dispositifs de commande électrique automatiques — Partie 1 : Exigences générales (norme IEC 60730-1:2013 adoptée, c
- CSA E60730-1A:15 (R2020) - Amendment 1:2017 to CSA E60730-1:15, Automatic electrical controls – Part 1: General requirements (Adopted amendment 1:2015 to IEC 60730-1:2013) | Modification 1:2017 de CSA E60730-1:15, Dispositifs de commande électrique automatiques — Partie 1 : Exigenc
- CAN/CSA-E60730-2-7:18 (R2022) - Automatic electrical controls — Part 2-7: Particular requirements for timers and time switches (Adopted IEC 60730-2-7:2015, third edition , 2015-03, with Canadian deviations)
- CAN/CSA-E60730-2-9:18 (R2023) - Automatic electrical controls — Part 2-9: Particular requirements for temperature sensing controls (Adopted IEC 60730-2-9:2018, edition 4:2015 consolidated with amendment 1:2018, with Canadian deviations)
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)