QUICK

TOP

해외표준 상세정보

관심표준 등록 : 표준업데이트 시 알림서비스

제공형태 더보기
  • subList_img01

    폐지

    판매

    CSA B64.10:17/CSA B64.10.1:17 (R2021)

    Selection and installation of backflow preventers / Maintenance and field testing of backflow preventers
    • 발행일 : 2017-01-01
    • 발행기관 : CSA
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어]보안PDF 281,000원

상세정보

분야
적용범위 Preface This volume contains the seventh edition of CSA B64.10, Selection and installation of backflow preventers, and the fourth edition of CSA B64.10.1, Maintenance and field testing of backflow preventers. CSA B64.10 supersedes the previous editions published in 2011, 2007, 2001, 1994, 1988 (as part of the CAN/CSA-B64 Series), and 1981. CSA B64.10.1 supersedes the previous editions published in 2011, 2007 and 2001.? This edition includes the following major changes:? a) updates to zone protection piping identification;? b) addition of emergency eye wash station for zone protection;? c) clarification on field testing installation;? d) addition of cross-connection control surveyor specifications;? e) removal of DCVAF double check valve for fire protection systems; and? f) addition of requirements for enclosures with no minimum thermal resistance (R) value.? The two Standards are intended as a guide for designers of potable water supply and plumbing systems in the selection of the proper type of device, for installers and owners in the installation and maintenance of the devices, and for inspection authorities in the testing of the devices after they have been installed. The Standards provide information on other methods of preventing contamination of potable water by backflow from back siphonage or back pressure.? CSA B64.10 and CSA B64.10.1 provide selection criteria, installation and maintenance procedures, and techniques that represent the general state of the art, but should not be construed as all-inclusive, especially where procedures and techniques are altered to meet special conditions. Where there are problems with a specific installation, it is suggested that the manufacturer of the backflow preventer be consulted.? ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------- B64.10-17 - Selection and installation of backflow preventers? Scope 1.1 Application? This Standard specifies requirements for the selection and installation of backflow preventers. Additional information on how backflow due to back siphonage and back pressure occurs, and how to select and apply specific devices, is included in Annexes A, B, and C.? 1.2 Exclusions? 1.2.1 This Standard does not specify requirements for materials, construction, or performance tests of backflow preventers. Such requirements are specified in the CSA B64 Series, in ASME A112.18.1/CSA B125.1, and in CSA B125.3. See Table 1.? 1.2.2 This Standard does not specify requirements for maintenance or field testing after the initial installation. Such requirements are specified in CSA B64.10.1.? 1.3 Terminology? In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.? Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.? Notes to tables and figures are considered part of the table or figure and may be written as requirements.? Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.? 1.4 Measurement? This Standard is written in SI (metric) units. For conversion tables, see Annex D. Vacuum is expressed in pressure below ambient.? ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------- B64.10.1-17 - Maintenance and field testing of backflow preventers? Scope 1.1 This Standard specifies requirements for the maintenance and field testing of backflow preventers.? 1.2 This Standard does not specify requirements for the selection and installation of backflow preventers. Such requirements are specified in CSA B64.10.? 1.3 In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.? Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.? Notes to tables and figures are considered part of the table or figure and may be written as requirements.? Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.? 1.4 This Standard is written in SI (metric) units. For conversion tables, see Annex D of CSA B64.10. Vacuum is expressed in pressure below ambient.
국제분류(ICS)코드
페이지수 162
Edition

이력정보

No. 표준번호 표준명 발행일 상태
1 CSA B64.10:23/CSA B64.10.1:23상세보기 Selection and installation of backflow preventers/Maintenance and field testing of backflow preventers 2023-01-01 표준
2 CSA B64.10:17/CSA B64.10.1:17 (R2021)상세보기 Selection and installation of backflow preventers / Maintenance and field testing of backflow preventers 2017-01-01 폐지
3 B64.10-11/B64.10.1-11 (R2016)상세보기 Selection and installation of backflow preventers/Maintenance and field testing of backflow preventers 2011-01-01 폐지

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)