    CSA ISO 17827-2:17 (R2021)

    Solid biofuels — Determination of particle size distribution for uncompressed fuels — Part 2: Vibrating screen method using sieves with aperture of 3,15 mm and below (Adopted ISO 17827-2:2016, first edition, 2016-05-15)
    • 발행일 : 2017-01-01
    • 발행기관 : CSA
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어]보안PDF 109,400원

상세정보

분야
적용범위 Preface This is the first edition of CAN/CSA-ISO 17827-2, Solid biofuels - Determination of particle size distribution for uncompressed fuels - Part 2: Vibrating screen method using sieves with aperture of 3,15 mm and below, which is an adoption without modification of the identically titled ISO (International Organization for Standardization) Standard 17827-2 (first edition, 2016-05-15).? For brevity, this Standard will be referred to as "CAN/CSA-ISO 17827-2" throughout.? This Standard is one of two Standards developed by ISO/TC 238 on Solid Biofuels that are being adopted by CSA Group under the series Determination of particle size distribution for uncompressed fuels, which consists of the following:? a) ISO 17827-1, Part 1: Oscillating screen method using sieves with apertures of 3,15 mm and above; and? b) ISO 17827-2, Part 2: Vibrating screen method using sieves with aperture of 3,15 mm and below.? This Standard specifies a method for the determination of the size distribution of particulate biofuels by the vibrating screen method. The method described is meant for particulate biofuels only, namely, materials that either have been reduced in size, such as most wood fuels, or are physically in a particulate form. This part of CAN/CSA-ISO 17827 applies to particulate uncompressed fuels with a nominal top size of 3,15 mm and below (e.g., sawdust).? Scope This part of ISO 17827 specifies a method for the determination of the size distribution of particulate biofuels by the vibrating screen method. The method described is meant for particulate biofuels only, namely, materials that either have been reduced in size, such as most wood fuels, or are physically in a particulate form. This part of ISO 17827 applies to particulate uncompressed fuels with a nominal top size of 3,15 mm and below (e.g. sawdust). ?
국제분류(ICS)코드
페이지수 25
Edition

이력정보

No. 표준번호 표준명 발행일 상태
1 ISO 17827-2:2024상세보기 Solid biofuels — Determination of particle size distribution for uncompressed fuels — Part 2: Vibrating screen method using sieves with apertures of 3,15 mm and below 2024-05-23 표준
2 CSA ISO 17827-2:17 (R2021)상세보기 Solid biofuels — Determination of particle size distribution for uncompressed fuels — Part 2: Vibrating screen method using sieves with aperture of 3,15 mm and below (Adopted ISO 17827-2:2016, first edition, 2016-05-15) 2017-01-01 표준
3 ISO 17827-2:2016상세보기 Solid biofuels — Determination of particle size distribution for uncompressed fuels — Part 2: Vibrating screen method using sieves with aperture of 3,15 mm and below 2016-05-10 구판

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)