해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
폐지
판매
CISPR 20:2006+AMD1:2013 CSV
Sound and television broadcast receivers and associated equipment -Immunity characteristics - Limits and methods of measurement- 발행일 : 2013-10-29
- 발행기관 : IEC
상세정보
분야 | CISPR/CIS/I : Electromagnetic compatibility of information technology equipment, multimedia equipment and receivers |
---|---|
적용범위 | CISPR 20:2006+A1:2013 applies to television broadcast receivers, sound broadcast receivers and associated equipment intended for use in the residential, commercial and light industrial environment. Describes the methods of measurement and specified limits applicable to sound and television receivers and to associated equipment with regard to their immunity characteristics to disturbing signals. This standard is also applicable to the immunity of outdoor units of direct to home (DTH) satellite receiving systems for individual reception. Immunity requirements are given in the frequency range 0 Hz to 400 GHz. Radio-frequency tests outside the specified frequency bands or concerning other phenomena than given in this standard are not required. The objective of this standard is to define the immunity test requirements for equipment defined in the scope in relation to continuous and transient, conducted and radiated disturbances including electrostatic discharges. These test requirements represent essential electromagnetic immunity requirements. Test requirements are specified for each port (enclosure or connector) considered. The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations which are included: - residential properties, e.g. houses, apartments, etc.; - retail outlets, e.g. shops, supermarkets, etc.; - business premises, e.g. offices, banks, etc.; - areas of public entertainment, e.g. cinemas, public bars, dance halls, etc.; - outdoor locations, e.g. petrol stations, car parks, amusement and sports centres, etc.; - light-industrial locations e.g. workshops, laboratories, service centres, etc.; - car and boat. Locations which are characterized by their mains power being supplied directly at low voltage from the public mains are considered to be residential, commercial or light industrial. This consolidated version consists of the sixth edition (2006) and its amendment 1 (2013). Therefore, no need to order amendment in addition to this publication. |
국제분류(ICS)코드 | 33.100.20 : 내성 |
페이지수 | 347 |
Edition | 6.1 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | CISPR 20:2006+AMD1:2013 CSV상세보기 | Sound and television broadcast receivers and associated equipment -Immunity characteristics - Limits and methods of measurement | 2013-10-29 | 폐지 |
2 | CISPR 20:2006/AMD1:2013상세보기 | Amemdment 1 - Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement | 2013-10-29 | 폐지 |
3 | CISPR 20:2006상세보기 | Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement | 2006-11-27 | 폐지 |
4 | CISPR 20:2002+AMD1:2002+AMD2:2004 CSV상세보기 | Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement | 2005-02-09 | 구판 |
5 | CISPR 20:2002/AMD2:2004상세보기 | Amendment 2 - Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement | 2004-12-14 | 구판 |
6 | CISPR 20:2002/AMD1:2002상세보기 | Amendment 1 - Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement | 2002-10-29 | 구판 |
7 | CISPR 20:2002상세보기 | Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement | 2002-02-26 | 구판 |
8 | CISPR 20:1998+AMD1:1999 CSV상세보기 | Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement | 1999-06-30 | 구판 |
9 | CISPR 20:1998/AMD1:1999상세보기 | Amendment 1 - Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement | 1999-03-05 | 구판 |
10 | CISPR 20:1998상세보기 | Sound and television broadcast receivers and associated equipment - Immunity characteristics - Limits and methods of measurement | 1998-08-19 | 구판 |
11 | CISPR 20:1996/AMD2:1997상세보기 | Amendment 2 - Limits and methods of measurement of immunity characteristics of sound and television broadcast receivers and associated equipment | 1997-08-01 | 구판 |
12 | CISPR 20:1996/AMD1:1997상세보기 | Amendment 1 - Limits and methods of measurement of immunity characteristics of sound and television broadcast receivers and associated equipment | 1997-02-18 | 구판 |
13 | CISPR 20:1996상세보기 | Limits and methods of measurement of immunity characteristics of sound and television broadcast receivers and associated equipment | 1996-02-20 | 구판 |
14 | CISPR 20:1990/AMD3:1994상세보기 | Amendment 3 - Limits and methods of measurement of immunity characteristics of sound and television broadcast receivers and associated equipment. | 1994-11-29 | 구판 |
15 | CISPR 20:1990/AMD1:1990/COR1:1993상세보기 | Corrigendum 1 to Amendment 1 - Limits and methods of measurement of immunity characteristics of sound and television broadcast receivers and associated equipment | 1993-12-01 | 구판 |
16 | CISPR 20:1990/AMD2:1993상세보기 | Amendment 2 - Limits and methods of measurement of immunity characteristics of sound and television broadcast receivers and associated equipment. | 1993-06-15 | 구판 |
17 | CISPR 20:1990/AMD1:1990상세보기 | Amendment 1 - Limits and methods of measurement of immunity characteristics of sound and television broadcast receivers and associated equipment | 1990-12-01 | 구판 |
18 | CISPR 20:1990상세보기 | Limits and methods of measurement of immunity characteristics of sound and television broadcast receivers and associated equipment. | 1990-07-15 | 구판 |
19 | CISPR 20:1985상세보기 | Measurement of the immunity of sound and television broadcast receivers and associated equipment in the frequency range 1.5 MHz to 30 MHz by the current-injection method - Guidance on immunity requirements for the reduction of interference caused by radio transmitters in the frequency range 26 MHz to 30 MHz | 1985-01-01 | 구판 |
관련상품
- 관련상품이 존재하지 않습니다.
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)