해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
표준
판매
IEC 60332-1-2:2004+AMD1:2015 CSV
Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame- 발행일 : 2015-07-28
- 발행기관 : IEC
상세정보
분야 | TC 20 : Electric cables |
---|---|
적용범위 | IEC 60332-1-2:2004+A1:2015 Specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. The apparatus is given in IEC 60332-1-1. NOTE 1 Testing to IEC 60332-1-2 may be performed simultaneously with that to IEC 60332-1-3 if required. Recommended requirements for performance are given in Annex A. IEC 60332-1-2 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm² total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. In these cases, the procedure given in IEC 60332-2-2 is recommended. NOTE 2 Since the use of insulated conductor or cable which retards flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation, it is recommended that wherever the risk of propagation is high, for example in long vertical runs of bunches of cables, special installation precautions should also be taken. It cannot be assumed that because the sample of cable complies with the performance requirements recommended in this standard, that a bunch of cables will behave in a similar manner. (See IEC 60332-3 series.) This consolidated version consists of the first edition (2004) and its amendment 1 (2015). Therefore, no need to order amendment in addition to this publication. |
국제분류(ICS)코드 |
13.220.40 : 자재 및 제품의 점화성 및 연소성
29.020 : 전기 공학 일반 29.060.20 : 케이블 |
페이지수 | 48 |
Edition | 1.1 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 60332-1-2:2004/AMD1:2015상세보기 | Amendment 1 - Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame | 2015-07-28 | 표준 |
2 | IEC 60332-1-2:2004+AMD1:2015 CSV상세보기 | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame | 2015-07-28 | 표준 |
3 | IEC 60332-1-2:2004상세보기 | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame | 2004-07-15 | 표준 |
관련상품
- IEC 60332-2:1989 - Tests on electric cables under fire conditions. Part 2: Test on a single small vertical insulated copper wire or cable
- IEC TS 60332-3:1992 - Tests on electric cables under fire conditions - Part 3: Tests on bunched wires or cables
- IEC 60332-1:1993 - Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable
- IEC 60332-1:1993/COR1:1993 - Corrigendum 1 - Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable
- IEC 60332-2-2:2004 - Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame
다른 사람이 함께 구입한 상품
- IEC 60754-2:2011+AMD1:2019 CSV - Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity
- IEC 60332-3-25:2018 - Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category D
- IEC 60071-1:2019 - Insulation co-ordination - Part 1: Definitions, principles and rules
- IEC 62271-102:2018 - High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches
- IEC 61439-1:2020 - Low-voltage switchgear and controlgear assemblies - Part 1: General rules
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)