해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
표준
판매
CISPR 16-1-2:2014+AMD1:2017 CSV
Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements- 발행일 : 2017-11-07
- 발행기관 : IEC
상세정보
분야 | CISPR/CIS/A : Radio-interference measurements and statistical methods |
---|---|
적용범위 | CISPR 16-1-2:2014+A1:2017 specifies the characteristics and performance of equipment for the measurement of radio disturbance voltages and currents in the frequency range 9 kHz to 1 GHz. It has the status of a basic EMC publication. Specifications for ancillary apparatus are included for artificial mains networks, current and voltage probes and coupling units for current injection on cables. It is intended that the requirements of this publication are fulfilled at all frequencies and for all levels of radio disturbance voltages and currents within the CISPR indicating range of the measuring equipment. Methods of measurement are covered in the CISPR 16-2 series, and further information on radio disturbance is given in CISPR 16-3, while uncertainties, statistics and limit modelling are covered in the CISPR 16-4 series. This second edition cancels and replaces the first edition published in 2003 and its Amendment 1 (2004) and Amendment 2 (2006). This edition constitutes a technical revision which includes the following significant technical changes with respect to the previous edition: - requirements from CISPR 22 for the AAN have been copied to this standard; - and the CDNE for measurement of disturbance voltage in the frequency range 30 MHz to 300 MHz is added. Keywords: electromagnetic compatibility,coupling, asymetric artificial network, coupling decoupling network equipment. This consolidated version consists of the second edition (2014) and its amendment 1 (2017). Therefore, no need to order amendment in addition to this publication. |
국제분류(ICS)코드 |
33.100.20 : 내성
33.100.10 : 방사 |
페이지수 | 391 |
Edition | 2.1 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | CISPR 16-1-2:2014/AMD1:2017상세보기 | Amendment 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements | 2017-11-07 | 표준 |
2 | CISPR 16-1-2:2014+AMD1:2017 CSV상세보기 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements | 2017-11-07 | 표준 |
3 | CAN/CSA-CISPR 16-1-2:15상세보기 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements (Adopted IEC CISPR 16-1-2:2014, second edition, 2014- | 2015-01-01 | 폐지 |
4 | CISPR 16-1-2:2014상세보기 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements | 2014-03-21 | 표준 |
5 | CISPR 16-1-2:2014 RLV상세보기 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Coupling devices for conducted disturbance measurements | 2014-03-21 | 표준 |
6 | CISPR 16-1-2:2003/COR1:2009상세보기 | Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances | 2009-01-12 | 구판 |
7 | CISPR 16-1-2:2003+AMD1:2004+AMD2:2006 CSV상세보기 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances | 2006-08-11 | 구판 |
8 | CISPR 16-1-2:2003/AMD2:2006상세보기 | Amendment 2 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances | 2006-07-17 | 구판 |
9 | CISPR 16-1-2:2003+AMD1:2004 CSV상세보기 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances | 2004-06-07 | 구판 |
10 | CISPR 16-1-2:2003/AMD1:2004상세보기 | Amendment 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances | 2004-04-21 | 구판 |
11 | CISPR 16-1-2:2003상세보기 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-2: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances | 2003-11-19 | 구판 |
관련상품
- CISPR 16-1:1999 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus
- CISPR TR 16-3:2000 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: Reports and recommendations of CISPR
- CISPR 16-4:2002 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4: Uncertainty in EMC measurements
- CISPR TR 16-3:2000/AMD1:2002 - Amendment 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: Reports and recommendations of CISPR
- CISPR 16-1:1999/AMD1:2002 - Amendment 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus
다른 사람이 함께 구입한 상품
- CISPR 16-1-5:2014+AMD1:2016 CSV - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
- SAE ARP958E - Electromagnetic Interference Measurement Antennas; Calibration Method
- BS EN IEC 61326-2-3:2021 - Electrical equipment for measurement, control and laboratory use. EMC requirements. Particular requirements. Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning.
- BS EN 55032:2015+A1:2020 - Electromagnetic compatibility of multimedia equipment. Emission requirements.
- BS EN IEC 61326-2-1:2021 - Electrical equipment for measurement, control and laboratory use. EMC requirements. Particular requirements. Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)