해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
표준
판매
IEC 62056-3-1:2021
Electricity metering data exchange - The DLMS/COSEM suite - Part 3-1: Use of local area networks on twisted pair with carrier signalling- 발행일 : 2021-07-07
- 발행기관 : IEC
상세정보
분야 | TC 13 : Electrical energy measurement and control |
---|---|
적용범위 | IEC 62056-3-1:2021 describes two sets of profiles: the first set of profiles allows a bidirectional communication between a client and a server. This set of profiles is made of three profiles allowing local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. Three different profiles are supported: • base profile: this three-layer profile provides remote communication services; NOTE 1 This first profile was published in IEC 61142:1993 and became known as the Euridis standard. • profile with DLMS: this profile allows using DLMS services as specified in IEC 61334 4 41; NOTE 2 This second profile was published in IEC 62056-31:1999. • profile with DLMS/COSEM: this profile allows using the DLMS/COSEM Application layer and the COSEM object model as specified in IEC 62056 5 3 and in IEC 62056 6 2 respectively. The three profiles use the same physical layer and they are fully compatible, meaning that devices implementing any of these profiles can be operated on the same bus. The transmission medium is twisted pair using carrier signalling and it is known as the Euridis Bus. The second set of profiles allows unidirectional communication between a given Energy Metering device and a Customer Energy Management System. This second set is made up of three profiles. Subclause 4.2.1 to Clause 8 included specify the bidirectional communication using twisted pair signalling and Clause 9 to 9.5 the unidirectional communication using twisted pair signalling. This second edition cancels and replaces the first edition of IEC 62056-3-1, issued in 2013, and constitutes a technical revision. The main technical changes with regard to the previous edition are as follows: • addition of a profile which makes use of the IEC 62056 DLMS/COSEM Application layer and COSEM object model; • review of the data link layer which is split into two parts: – a pure Data Link layer; – a "Support Manager" entity managing the communication media; • ability to negotiate the communication speed, bringing baud rate up to 9 600 bauds. |
국제분류(ICS)코드 |
35.110 : 네트워킹
91.140.50 : 전기 공급 체계 17.220.20 : 전기 및 자기량 측정 |
페이지수 | 258 |
Edition | 2.0 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 62056-3-1:2021상세보기 | Electricity metering data exchange - The DLMS/COSEM suite - Part 3-1: Use of local area networks on twisted pair with carrier signalling | 2021-07-07 | 표준 |
2 | IEC 62056-3-1:2021 RLV상세보기 | Electricity metering data exchange - The DLMS/COSEM suite - Part 3-1: Use of local area networks on twisted pair with carrier signalling | 2021-07-07 | 표준 |
3 | IEC 62056-3-1:2013상세보기 | Electricity metering data exchange - The DLMS/COSEM suite - Part 3-1: Use of local area networks on twisted pair with carrier signalling | 2013-08-20 | 구판 |
관련상품
- IEC TS 62056-41:1998 - Electricity metering - Data exchange for meter reading, tariff and load control - Part 41: Data exchange using wide area networks: Public switched telephone network (PSTN) with LINK+ protocol
- IEC TS 62056-52:1998 - Electricity metering - Data exchange for meter reading, tariff and load control - Part 52: Communication protocols management distribution line message specification (DLMS) server
- IEC TS 62056-51:1998 - Electricity metering - Data exchange for meter reading, tariff and load control - Part 51: Application layer protocols
- IEC 62056-31:1999 - Electricity metering - Data exchange for meter reading, tariff and load control - Part 31: Use of local area networks on twisted pair with carrier signalling
- IEC 62056-42:2002 - Electricity metering - Data exchange for meter reading, tariff and load control - Part 42: Physical layer services and procedures for connection-oriented asynchronous data exchange
다른 사람이 함께 구입한 상품
- KS C 1214(2022 확인) - 전자식 유효/무효 전력량계(유효 0.2급/0.5급, 1.0급/2.0급, 무효2.0급/3.0급)
- IEC 62056-7-6:2013 - Electricity metering data exchange - The DLMS/COSEM suite - Part 7-6: The 3-layer, connection-oriented HDLC based communication profile
- IEC 62056-8-4:2018 - Electricity metering data exchange - The DLMS/COSEM suite - Part 8-4: Communication profiles for narrow-band OFDM PLC PRIME neighbourhood networks
- IEC 62056-1-0:2014 - Electricity metering data exchange - The DLMS/COSEM suite - Part 1-0: Smart metering standardisation framework
- KS C IEC 62056-5-3(2018 확인) - 전기 계량 데이터 교환-DLMS/COSEM 스위트-제5-3부:DLMS/COSEM 응용계층
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)