IEC 61970-456:2021
Energy management system application program interface (EMS-API) - Part 456: Solved power system state profiles- 발행일 : 2021-12-15
- 발행기관 : IEC
상세정보
| 분야 | TC 57 : Power systems management and associated information exchange |
|---|---|
| 적용범위 | IEC 61970-456:2021 belongs to the IEC 61970-450 to IEC 61970-499 series that, taken as a whole, defines at an abstract level the content and exchange mechanisms used for data transmitted between power system analyses applications, control centres and/or control centre components. The purpose of this document is to rigorously define the subset of classes, class attributes, and roles from the CIM necessary to describe the result of state estimation, power flow and other similar applications that produce a steady-state solution of a power network, under a set of use cases which are included informatively in this document. This document is intended for two distinct audiences, data producers and data recipients, and can be read from those two perspectives. From the standpoint of model export software used by a data producer, the document defines how a producer may describe an instance of a network case in order to make it available to some other program. From the standpoint of a consumer, the document defines what that importing software must be able to interpret in order to consume power flow cases. There are many different use cases for which use of this document is expected and they differ in the way that the document will be applied in each case. Implementers are expected to consider what use cases they wish to cover in order to know the extent of different options they must cover. As an example, the profiles defined in this document will be used in some cases to exchange starting conditions rather than solved conditions, so if this is an important use case, it means that a consumer application needs to be able to handle an unsolved state as well as one which has met some solution criteria. This third edition cancels and replaces the second edition published in 2018. This edition constitutes a technical revision. It is based on the IEC 61970 UML version ‘IEC61970CIM17v40’, dated 2020-08-24. This edition includes the following significant technical changes with respect to the previous edition: a) Updated to support CIM17 (IEC 61970-301:2020+AMD1) and align with IEC 61970‑452:ED4. b) The classes PowerElectronicsConnection, PowerElectronicsUnit and PowerElectronicsWindUnit are added to the Steady State Hypothesis (SSH) profile to match the changes done for Edition 4 of IEC 61970-452 , Core Equipment profile. c) Added relevant terms used in this document. d) Clarified use of Equipment.inService and Equipment.normallyInService. |
| 국제분류(ICS)코드 | 33.200 : 원격 제어. 원격 측정 |
| 페이지수 | 217 |
| Edition | 3.0 |
이력정보
| No. | 표준번호 | 표준명 | 발행일 | 상태 |
|---|---|---|---|---|
| 1 | IEC 61970-456:2021상세보기 | Energy management system application program interface (EMS-API) - Part 456: Solved power system state profiles | 2021-12-15 | 표준 |
| 2 | IEC 61970-456:2018상세보기 | Energy management system application program interface (EMS-API) - Part 456: Solved power system state profiles | 2018-03-19 | 구판 |
| 3 | IEC 61970-456:2013+AMD1:2015 CSV상세보기 | Energy management system application program interface (EMS-API) -Part 456: Solved power system state profiles | 2015-09-29 | 구판 |
| 4 | IEC 61970-456:2013/AMD1:2015상세보기 | Amendment 1 - Energy management system application program interface (EMS-API) - Part 456: Solved power system state profiles | 2015-09-29 | 구판 |
| 5 | IEC 61970-456:2013상세보기 | Energy management system application program interface (EMS-API) - Part 456: Solved power system state profiles | 2013-05-07 | 구판 |
관련상품
- IEC TS 61970-2:2004 - Energy management system application program interface (EMS-API) - Part 2: Glossary
- IEC TS 61970-401:2005 - Energy management system application program interface (EMS-API) - Part 401: Component interface specification (CIS) framework
- IEC 61970-1:2005 - Energy management system application program interface (EMS-API) - Part 1: Guidelines and general requirements
- IEC 61970-501:2006 - Energy management system application program interface (EMS-API) - Part 501: Common Information Model Resource Description Framework (CIM RDF) schema
- IEC 61970-407:2007 - Energy management system application program interface (EMS-API) - Part 407: Time Series Data Access (TSDA)
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO/TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO/TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)PDF+PRINT :
직접 파일 다운로드 및 인쇄본 우편발송(2~3일 소요)보안PDF+PRINT :
직접 파일 다운로드 및 인쇄본 우편발송(2~3일 소요)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능ASME PBVC Plus :
인쇄본 우편발송 및 온라인 구독(1User용, 2년)