IEC TR 61850-7-510:2021
Communication networks and systems for power utility automation - Part 7-510: Basic communication structure - Hydroelectric power plants, steam and gas turbines - Modelling concepts and guidelines- 발행일 : 2021-12-16
- 발행기관 : IEC
상세정보
분야 | TC 57 : Power systems management and associated information exchange |
---|---|
적용범위 | IEC TR 61850-7-510:2021(E), which is a technical report, is intended to provide explanations on how to use the Logical Nodes defined in IEC 61850-7-410 as well as other documents in the IEC 61850 series to model complex control functions in power plants, including variable speed pumped storage power plants. IEC 61850-7-410 introduced the general modelling concepts of IEC 61850 for power plants. It is however not obvious from the standard how the modelling concepts can be implemented in actual power plants. This document explains how the data model and the concepts defined in the IEC 61850 standard can be applied in Hydro; both directly at the process control level, but also for data structuring and data exchange at a higher level. Application of the data model for Thermal is limited to power evacuation (in principle the extraction of the generated electrical power) and the prime mover shaft and bearing system. The interfaces of the fuel and steam valves are modelled for the purpose of process control. Communication services, and description of the use of mappings of the IEC 61850 data model to different communication protocols, are outside the scope of this document. This second edition cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Process modelling according to IEC 61850-6:2009, including IEC 61850-6:2009/AMD1:2018. b) Examples of application of Reference Designation System together with the process modelling, in particular application of IEC/ISO 81346. c) Description of modelling related to Steam- and Gas turbines. d) Annexes with examples of application of SCL according to the examples in the Technical Report. e) The dynamic exchange of values by using polling, GOOSE, Reporting or Sampled Values is no longer included in the Technical Report. |
국제분류(ICS)코드 | 33.200 : 원격 제어. 원격 측정 |
페이지수 | 169 |
Edition | 2.0 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC TR 61850-7-510:2021상세보기 | Communication networks and systems for power utility automation - Part 7-510: Basic communication structure - Hydroelectric power plants, steam and gas turbines - Modelling concepts and guidelines | 2021-12-16 | 표준 |
2 | IEC TR 61850-7-510:2012상세보기 | Communication networks and systems for power utility automation - Part 7-510: Basic communication structure - Hydroelectric power plants - Modelling concepts and guidelines | 2012-03-22 | 구판 |
관련상품
- IEC 61850-9-1:2003 - Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link
- IEC 61850-6:2009 - Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs
- IEC TR 61850-90-1:2010 - Communication networks and systems for power utility automation - Part 90-1: Use of IEC 61850 for the communication between substations
- IEC 61850-7-4:2010 - Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes
- IEC 61850-7-2:2010 - Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI)
다른 사람이 함께 구입한 상품
- IEC TR 61850-90-5:2012 - Communication networks and systems for power utility automation - Part 90-5: Use of IEC 61850 to transmit synchrophasor information according to IEEE C37.118
- IEC TR 61850-90-8:2016 - Communication networks and systems for power utility automation - Part 90-8: Object model for E-mobility
- IEC TR 61850-90-17:2017 - Communication networks and systems for power utility automation - Part 90-17: Using IEC 61850 to transmit power quality data
- IEC TS 61850-80-1:2016 - Communication networks and systems for power utility automation - Part 80-1: Guideline to exchanging information from a CDC-based data model using IEC 60870-5-101 or IEC 60870-5-104
- IEC TS 61850-2:2019 - Communication networks and systems for power utility automation - Part 2: Glossary
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)