IEC 62271-202:2022/COR1:2023
Corrigendum 1 - High-voltage switchgear and controlgear - Part 202: AC prefabricated substations for rated voltages above 1 kV and up to and including 52 kV- 발행일 : 2023-08-24
- 발행기관 : IEC
-
정오표(corrigenda, 正誤表)란?
원문내용 중 잘못된 글자나 문구를 바로잡아 만든 일람표.
상세정보
분야 | TC 17/SC 17C : Assemblies |
---|---|
적용범위 | IEC 62271-202:2022 specifies the service conditions, rated characteristics, general structural requirements and test methods of enclosed high-voltage prefabricated substations. These prefabricated substations are cable-connected to AC high-voltage networks with an operating voltage up to and including 52 kV and power frequencies up to and including 60 Hz. They can be manually operated from inside (walk-in type) or from outside (non-walk-in type). They are designed for outdoor installation at locations with public accessibility and where protection of personnel is provided. This third edition cancels and replaces the second edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: the whole document contents and structure are reviewed with due consideration of IEC 62271-1:2017; modification of the title and scope to include high-voltage switchgear prefabricated substations; inclusion of CEADS as a possible component of MV/LV prefabricated substation; in 7.2.101, the possible influence of surrounding elements on the dielectric performance of high-voltage components as high-voltage switchgear and controlgear and high-voltage interconnections non-metal-enclosed or without earthed screen are now considered; new informative Annex G with testing procedure to evaluate the impact of solar radiation in temperatures inside the enclosure and how to apply it; new informative Annex H for appropriate consideration of installation conditions of electronic equipment; the rated power of a prefabricated substation is now defined as a three-parameter rated value. See 5.101.1; minimum dimensions for access doors to the prefabricated substation in 6.104.4 and for free height of operation aisle in 6.105.3 have been introduced; continuous current (temperature rise) test methods have been revised/clarified where necessary; Figure D.1, which shows the mineral-oil-immersed power transformer load factor inside the enclosure, has been corrected. |
국제분류(ICS)코드 | 29.130.10 : 고전압 스위치 기어 및 콘트롤 기어 |
페이지수 | 2 |
Edition | 3.0 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 62271-202:2022/COR1:2023상세보기 | Corrigendum 1 - High-voltage switchgear and controlgear - Part 202: AC prefabricated substations for rated voltages above 1 kV and up to and including 52 kV | 2023-08-24 | 표준 |
2 | IEC 62271-202:2022상세보기 | High-voltage switchgear and controlgear - Part 202: AC prefabricated substations for rated voltages above 1 kV and up to and including 52 kV | 2022-06-22 | 표준 |
3 | IEC 62271-202:2014/COR1:2015상세보기 | Corrigendum 1 - High-voltage switchgear and controlgear - Part 202: High-voltage/low-voltage prefabricated substation | 2015-04-23 | 구판 |
4 | IEC 62271-202:2014상세보기 | High-voltage switchgear and controlgear - Part 202: High-voltage/ low-voltage prefabricated substation | 2014-03-27 | 구판 |
5 | IEC 62271-202:2006상세보기 | High-voltage switchgear and controlgear - Part 202: High-voltage/low voltage prefabricated substation | 2006-06-13 | 구판 |
관련상품
- IEC PAS 62271-109:2002 - High-voltage switchgear and controlgear - Part 109: Alternating-current series capacitor by-pass switches
- IEC TR 62271-308:2002 - High-voltage switchgear and controlgear - Part 308: Guide for asymmetrical short-circuit breaking test duty T100a
- IEC 62271-2:2003 - High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above
- IEC TR 62271-300:2006 - High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers
- IEC 62271-205:2008 - High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)