QUICK

TOP

해외표준 상세정보

관심표준 등록 : 표준업데이트 시 알림서비스

제공형태 더보기
  • subList_img01

    표준

    판매

    IEC 62305-3:2024

    Protection against lightning - Part 3: Physical damage to structures and life hazard
    • 발행일 : 2024-09-12
    • 발행기관 : IEC
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어/불어]PDF 723,000원

    • [영어/불어]PRINT 723,000원

상세정보

분야 TC 81 : Lightning protection
적용범위 IEC 62305-3:2024 provides the requirements for protection of a structure against physical damage by means of a lightning protection system (LPS), and for protection against injury to human beings due to touch and step voltages in the vicinity of an LPS (see IEC 62305-1).
This document is applicable to the:
a) design, installation, inspection and maintenance of an LPS for structures without limitation of their height,
b) establishment of measures for protection against injury to human beings primarily due to touch and step voltages.
This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Minimum thicknesses of metal sheets or metal pipes are given in Table 4 for air-termination systems where it is necessary to prevent hot-spot problems. Maximum temperature rises ΔT (K) and time duration t50 (s) for different thicknesses and long strokes are also given.
b) Cross-reference to the IEC 62561 series is made for the use of reliable, stable, safe and appropriate LPS components.
c) The application of two methods – general and simplified – for separation distance calculation is clarified.
d) Some changes to the requirements for continuity of steel reinforcement are made.
e) Annex C is revised to address comments from IEC subcommittee 31J.
f) Revision of positioning of air-termination conductors are modified according to the three accepted methods. A more precise description of the methods for positioning of the air-termination systems are made according to the complexity of structures to be protected. The main text has been simplified, Annex A has been deleted and all detailed information has been moved to Annex D.
g) Information on the protection of green roofs is introduced in Annex D.
h) Information on the protection of protruding parts on facades of tall buildings is introduced in Annex D.
i) a new definition of “electrically insulated LPS” has been introduced to distinguish it from an LPS both electrically and physically isolated from the structure, with a slight modification of the other LPS definitions.
국제분류(ICS)코드 29.020 : 전기 공학 일반
91.120.40 : 피뢰
페이지수 280
Edition 3.0

이력정보

No. 표준번호 표준명 발행일 상태
1 IEC 62305-3:2024상세보기 Protection against lightning - Part 3: Physical damage to structures and life hazard 2024-09-12 표준
2 IEC 62305-3:2010상세보기 Protection against lightning - Part 3: Physical damage to structures and life hazard 2010-12-09 구판
3 IEC 62305-3:2006상세보기 Protection against lightning - Part 3: Physical damage to structures and life hazard 2006-01-17 구판

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)