해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-

표준
판매
IEC 61850-7-410:2026
Communication networks and systems for power utility automation - Part 7-410: Basic communication structure - Hydroelectric power plants, steam and gas turbines - Logical node classes- 발행일 : 2026-07-16
- 발행기관 : IEC
상세정보
| 분야 | TC 57 : Power systems management and associated information exchange |
|---|---|
| 적용범위 | IEC 61850-7-410:2026 specifies the logical node classes for use in the domain of hydroelectric power stations, steam and gas turbines. This IEC61850 domain information model standard utilizes the existing Logical Node (LN) classes defined in IEC 61850-7-4, Basic communication structure – Compatible logical node classes and data object classes where possible, while defining new and extended domain specific LN classes to provide the necessary data objects for application to functions and systems in the domain of hydroelectric power stations, steam and gas turbines. The domain information model includes the interface towards a central operator centre’s control functions. The Scope of this document, related to steam and gas turbine specifics, is limited to overall control functions and generator and turbine control functions. For hydroelectric power, the scope includes the entire power station automation system. Edition 3 is intended to form a basis for extensions in local implementations. Such extensions may be defined in profiles. Many of the Logical Nodes defined in this document are designed to be suitable for use in domains beyond the scope of hydro power plants and steam and gas turbines. A suggested structure of the Logical Nodes into packages for integration with other domains is provided in Annex G (informative), Migration of this document to the future edition of IEC 61850. This third edition cancels and replaces the second edition published in 2012 and Amendment 1:2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) New concepts and constructs for modelling of large power generation; b) Addition of new Logical Nodes to cover systems and details of the power generation domain previously not modelled in a sufficient way; c) Review of existing Logical Nodes concerning structure, use of Common Data Classes and naming; d) Fixes and improvements of some names and descriptions of Data Objects; e) Improvements of the structure and enumerations within the Domain Logical Nodes; f) Addition of new Logical Nodes with respect to maintenance and supervision functionality; g) Updating of Logical Nodes for PSS functionality (LNs: APSS, APST and APSF) reflecting the updated PSS standard IEEE 421.5:2016; h) Incorporation of Amendment 1, including among other things the Group E Logical Nodes; i) Resolutions to all known UML Issues related to IEC 61850-7-410; j) This 3rd edition is autogenerated from the UML file; k) Upon publication the updated IEC 61850-7-410 NameSpace will be made available as a Code Component on the TC57 web page. In the Edition 3 of this document, a new modelling approach is applied. In order to achieve greater efficiency and harmonization of the IEC 61850 information model by streamlining the Namespaces it is divided into, the structure of the latest revisions of the Namespaces related to the power generation domain, aims to: – share common concepts, approaches, and models in the generation domains, – increase the modularity of the model itself and enable its extension. This edition hence introduces a new modeling approach, which is further explained in Clause 5. The pillars upon which the new approach is founded are as follows: – a layered architecture for the power station model, in accordance with the control hierarchy concepts defined in IEC 60050-351-55; – a comprehensive review of the models considering the approach outlined in IEC 61850-7-420:2021, aimed at harmonizing fundamental concepts in the power generation domain; – a systematic alignment with the concepts outlined in IEC 61850-7-500:2017. Specific aspects typical of the large power generation domain are also addressed in the present document. The relationship between concepts described in this document and the ones of related standards can be found in Annex B and Annex C. In addition to this objective, Edition 3 provides clarifications on the purposes and intended use of such information model in a new set of explanatory clauses, which were not present in the previous editions. |
| 국제분류(ICS)코드 | 33.200 : 원격 제어. 원격 측정 |
| 페이지수 | 1484 |
| Edition | 3.0 |
이력정보
| No. | 표준번호 | 표준명 | 발행일 | 상태 |
|---|---|---|---|---|
| 1 | IEC 61850-7-410:2026상세보기 | Communication networks and systems for power utility automation - Part 7-410: Basic communication structure - Hydroelectric power plants, steam and gas turbines - Logical node classes | 2026-07-16 | 표준 |
| 2 | IEC 61850-7-410:2012+AMD1:2015 CSV상세보기 | Communication networks and systems for power utility automation - Part 7-410: Basic communication structure - Hydroelectric power plants - Communication for monitoring and control | 2015-11-12 | 구판 |
| 3 | IEC 61850-7-410:2012/AMD1:2015상세보기 | Amendment 1 - Communication networks and systems for power utility automation - Part 7-410: Basic communication structure - Hydroelectric power plants - Communication for monitoring and control | 2015-11-12 | 구판 |
| 4 | IEC 61850-7-410:2012상세보기 | Communication networks and systems for power utility automation - Part 7-410: Basic communication structure - Hydroelectric power plants - Communication for monitoring and control | 2012-10-30 | 구판 |
| 5 | IEC 61850-7-410:2007상세보기 | Communication networks and systems for power utility automation - Part 7-410: Hydroelectric power plants - Communication for monitoring and control | 2007-08-10 | 구판 |
관련상품
- IEC 61850-9-1:2003 - Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link
- IEC 61850-6:2009 - Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs
- IEC TR 61850-90-1:2010 - Communication networks and systems for power utility automation - Part 90-1: Use of IEC 61850 for the communication between substations
- IEC 61850-7-4:2010 - Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes
- IEC 61850-7-2:2010 - Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI)
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO/TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO/TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)PDF+PRINT :
직접 파일 다운로드 및 인쇄본 우편발송(2~3일 소요)보안PDF+PRINT :
직접 파일 다운로드 및 인쇄본 우편발송(2~3일 소요)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능ASME PBVC Plus :