해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
구판
판매
ISO 13344:2004
Estimation of the lethal toxic potency of fire effluents- 발행일 : 2004-10-14
- 발행기관 : ISO
상세정보
분야 | ISO/TC 92/SC 3 : Fire threat to people and environment |
---|---|
적용범위 | ISO 13344:2004 provides a means for estimating the lethal toxic potency of the fire effluents produced from a material while exposed to the specific combustion conditions of a physical fire model. The lethal toxic potency values are specifically related to the fire model selected, the exposure scenario and the material evaluated. Lethal toxic potency values associated with 30-min exposures of rats are predicted using calculations which employ combustion atmosphere analytical data for carbon monoxide (CO), carbon dioxide (CO2), oxygen (O2) (vitiation) and, if present, hydrogen cyanide (HCN), hydrogen chloride (HCl), hydrogen bromide (HBr), hydrogen fluoride (HF), sulfur dioxide (SO2), nitrogen dioxide (NO2), acrolein and formaldehyde. If the fire effluent toxic potency cannot be attributed to the toxicants analysed, this is an indication that other toxicants or factors must be considered. ISO 13344:2004 is applicable to the estimation of the lethal toxic potency of fire effluent atmospheres produced from materials, products or assemblies under controlled laboratory conditions and should not be used in isolation to describe or appraise the toxic hazard or risk of materials, products or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire hazard assessment that takes into account all of the factors, which are pertinent to an assessment of the fire hazard of a particular end use; see ISO/TS 19706. The intended use of fire safety-engineering calculations is for life-safety prediction for people and is most frequently for time intervals somewhat shorter than 30 min. This extrapolation across species and exposure intervals is outside the scope of ISO 13344:2004. ISO 13344:2004 does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of ISO 13344:2004 to establish appropriate safety and health practices. |
국제분류(ICS)코드 | 13.220.99 : 방화에 관련된 기타 규격 |
페이지수 | 14 |
Edition | 2 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ISO 13344:2015상세보기 | Estimation of the lethal toxic potency of fire effluents | 2015-12-01 | 표준 |
2 | ISO 13344:2004상세보기 | Estimation of the lethal toxic potency of fire effluents | 2004-10-14 | 구판 |
3 | ISO 13344:1996상세보기 | Determination of the lethal toxic potency of fire effluents | 1996-12-12 | 구판 |
관련상품
- 관련상품이 존재하지 않습니다.
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)