    ISO 80601-2-13:2011

    Medical electrical equipment — Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation
    • 발행일 : 2011-08-08
    • 발행기관 : ISO
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어]PDF 113,000원

    • [영어]PRINT 113,000원

상세정보

분야 ISO/TC 121/SC 1 : Breathing attachments and anaesthetic machines
적용범위

ISO/IEC 80601-2-13:2011 is applicable to the basic safety and essential performance of an anaesthetic workstation for administering inhalational anaesthesia whilst continuously attended by a professional operator.

ISO/IEC 80601-2-13:2011 specifies particular requirements for a complete anaesthetic workstation and the following anaesthetic workstation components which, although considered as individual devices in their own right, may be utilized, in conjunction with other relevant anaesthetic workstation components, to form an anaesthetic workstation to a given specification:

  • anaesthetic gas delivery system;
  • anaesthetic breathing system;
  • anaesthetic gas scavenging system;
  • anaesthetic vapour delivery system;
  • anaesthetic ventilator;
  • monitoring equipment;
  • alarm system;
  • protection device.

ISO/IEC 80601-2-13:2011 is also applicable to those accessories intended by their manufacturer to be connected to an anaesthetic workstation where the characteristics of those accessories can affect the basic safety and essential performance of the anaesthetic workstation.

If a clause or subclause is specifically intended to be applicable to anaesthetic workstation components only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to an anaesthetic workstation and its individual components, as relevant.

Hazards inherent in the intended physiological function of an anaesthetic workstation and its individual components within the scope of ISO/IEC 80601-2-13:2011 are not covered by specific requirements in ISO/IEC 80601-2-13:2011 except in 7.2.13 and 8.4.1 of IEC 60601-1:2005.

ISO/IEC 80601-2-13:2011 is not applicable to any anaesthetic workstation intended for use with flammable anaesthetic agents, as determined by Annex BB.

국제분류(ICS)코드 11.040.10 : 마취제. 호흡 및 소생장비
페이지수 99
Edition 1

이력정보

No. 표준번호 표준명 발행일 상태
1 ISO 80601-2-13:2022상세보기 Medical electrical equipment — Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation 2022-04-29 표준
2 ISO 80601-2-13:2011/Amd 2:2018상세보기 Medical electrical equipment — Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation — Amendment 2 2018-07-19 구판
3 ISO 80601-2-13:2011/Amd 1:2015상세보기 Medical electrical equipment — Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation — Amendment 1 2015-03-06 구판
4 ISO 80601-2-13:2011상세보기 Medical electrical equipment — Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation 2011-08-08 구판
5 ISO 80601-2-13:2022/DAmd 1상세보기 Medical electrical equipment — Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation — Amendment 1 초안

다른 사람이 함께 구입한 상품

  • 함께 구입한 상품이 존재하지 않습니다.

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)