    ISO 10993-6:2016

    Biological evaluation of medical devices — Part 6: Tests for local effects after implantation
    • 발행일 : 2016-11-28
    • 발행기관 : ISO
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어]PDF 269,500원

    • [영어]PRINT 269,500원

상세정보

분야 ISO/TC 194 : Biological and clinical evaluation of medical devices
적용범위

ISO 10993-6:2016 specifies test methods for the assessment of the local effects after implantation of biomaterials intended for use in medical devices.

ISO 10993-6:2016 applies to materials that are

- solid and non-absorbable,

- non-solid, such as porous materials, liquids, gels, pastes, and particulates, and

- degradable and/or absorbable, which may be solid or non-solid.

The test sample is implanted into a site and animal species appropriate for the evaluation of the biological safety of the material. These implantation tests are not intended to evaluate or determine the performance of the test sample in terms of mechanical or functional loading. This part of ISO 10993 can also be applied to medical devices that are intended to be used topically in clinical indications where the surface or lining might have been breached, in order to evaluate local tissue responses.

The local effects are evaluated by a comparison of the tissue response caused by a test sample to that caused by control materials used in medical devices whose clinical acceptability and biocompatibility characteristics have been established. The objective of the test methods is to characterize the history and evolution of the tissue response after implantation of a medical device/biomaterial including final integration or absorption/degradation of the material. In particular for degradable/absorbable materials, the degradation characteristics of the material and the resulting tissue response should be determined.

ISO 10993-6:2016 does not deal with systemic toxicity, carcinogenicity, teratogenicity or mutagenicity. However, the long-term implantation studies intended for evaluation of local biological effects might provide insight into some of these properties. Systemic toxicity studies conducted by implantation might satisfy the requirements of this part of ISO 10993. When conducting combined studies for evaluating local effects and systemic effects, the requirements of both standards is to be fulfilled.

국제분류(ICS)코드 11.100.20 : 의료 장비의 생물학적 평가
페이지수 29
Edition 3

이력정보

No. 표준번호 표준명 발행일 상태
1 ISO 10993-6:2016상세보기 Biological evaluation of medical devices — Part 6: Tests for local effects after implantation 2016-11-28 표준
2 ISO 10993-6:2007상세보기 Biological evaluation of medical devices — Part 6: Tests for local effects after implantation 2007-04-04 구판
3 ISO 10993-6:1994상세보기 Biological evaluation of medical devices — Part 6: Tests for local effects after implantation 1994-07-07 구판
4 ISO/DIS 10993-6상세보기 Biological evaluation of medical devices — Part 6: Tests for local effects after implantation 폐지

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)