해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
구판
판매
ASTM E336-15
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings- 발행일 : 2015-09-01
- 발행기관 : ASTM
상세정보
분야 | 04.06 : 보온, 방음 |
---|---|
적용범위 | 1.1 The sound isolation between two spaces in a building is determined by a combination of the direct transmission through the nominally separating building element (as normally measured in a laboratory) and any transmission along a number of indirect paths, usually referred to as flanking paths. Fig. 1 illustrates the direct paths and some possible structural flanking paths. Additional non-structural flanking paths may include transmission through common air ducts between rooms, or doors to the corridor from adjacent rooms. 1.2 The main part of this test method defines procedures and metrics to assess the sound isolation between two rooms or portions thereof in a building separated by a common partition including both direct and flanking transmission paths or the apparent sound insulation of the separating partition. Appropriate measures and their single number ratings are the noise reduction (NR) and noise isolation class (NIC), the normalized noise reduction (NNR) and normalized noise isolation class (NNIC), and the apparent transmission loss (ATL) and apparent sound transmission class (ASTC). With the exception of the ATL and ASTC under specified conditions, these procedures in the main part of the test method are only applicable when both room volumes are less than 150 m3. Note 1: The word “partition” in this test method includes all types of walls, floors, or any other boundaries separating two spaces. The boundaries may be permanent, operable, or movable. 1.3 The NR and NIC between two locations may always be measured and reported though conditions present will influence how measurements are made. Restrictions such as minimum room volume or dimensions or maximum room absorption are imposed for all other measures and ratings in this standard. Thus, conditions may exist that will not allow NNR (NNIC), ATL (ASTC) or FTL (FSTC) to be measured. Where a partition between rooms is composed of parts that are constructed differently, or contains an element such as a door, it is not possible to measure the ATL and ASTC of the individual elements or portions of the partition. To evaluate the field performance of a door less than 6 m2 in area, use Test Method E2964. 1.4 Annex A1 provides methods to assess the sound transmission through a partition or partition element with the influence of flanking transmission reduced. These methods may be used when it must be demonstrated that a partition has achieved a specified minimum sound attenuation. The results are the field transmission loss (FTL) and field sound transmission class (FSTC). 1.5 Annex A2 provides methods to measure the sound isolation between portions of two rooms in a building separated by a common partition including both direct and flanking paths when at least one of the rooms has a volume of 150 m3 or more. The results are the noise reduction (NR) and noise isolation class (NIC). 1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.7 The text of this test method references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.8 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
국제분류(ICS)코드 | |
페이지수 | 15 |
Edition | 15 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ASTM E336-24상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2024-09-01 | 표준 |
2 | ASTM E336-24 REDLINE상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2024-09-01 | 표준 |
3 | ASTM E336-23 REDLINE상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2023-01-01 | 구판 |
4 | ASTM E336-23상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2023-01-01 | 구판 |
5 | ASTM E336-20상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2020-04-01 | 구판 |
6 | ASTM E336-20 REDLINE상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2020-04-01 | 구판 |
7 | ASTM E336-19a REDLINE상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2019-10-01 | 구판 |
8 | ASTM E336-19a상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2019-10-01 | 구판 |
9 | ASTM E336-19상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2019-01-01 | 구판 |
10 | ASTM E336-19 REDLINE상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2019-01-01 | 구판 |
11 | ASTM E336-17a상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2017-11-15 | 구판 |
12 | ASTM E336-17a REDLINE상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2017-11-15 | 구판 |
13 | ASTM E336-17상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2017-07-01 | 구판 |
14 | ASTM E336-16a상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2016-10-01 | 구판 |
15 | ASTM E336-16상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2016-01-01 | 구판 |
16 | ASTM E336-15상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2015-09-01 | 구판 |
17 | ASTM E336-14상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2014-04-15 | 구판 |
18 | ASTM E336-11상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2011-11-01 | 구판 |
19 | ASTM E336-10상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2010-09-01 | 구판 |
20 | ASTM E336-09상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2009-09-01 | 구판 |
21 | ASTM E336-08상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2008-11-01 | 구판 |
22 | ASTM E336-07상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2007-10-01 | 구판 |
23 | ASTM E336-05상세보기 | Standard Test Method for Measurement of Airborne Sound Insulation in Buildings | 2005-04-01 | 구판 |
24 | ASTM E336-97e1상세보기 | Standard Test Method for Measurement of Airborne Sound Insulation in Buildings | 1997-03-10 | 구판 |
25 | ASTM E336-97상세보기 | Standard Test Method for Measurement of Airborne Sound Insulation in Buildings | 1997-03-10 | 구판 |
관련상품
- 관련상품이 존재하지 않습니다.
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)