ASTM E336-19a
Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings- 발행일 : 2019-10-01
- 발행기관 : ASTM
상세정보
분야 | 04.06 : 보온, 방음 |
---|---|
적용범위 | 1.1 The sound isolation between two spaces in a building is influenced most strongly by a combination of the direct transmission through the nominally separating building element (as normally measured in a laboratory) and any transmission along a number of indirect paths, referred to as flanking paths. Fig. 1 illustrates the direct paths (D) and some possible structural flanking paths (F). Additional non-structural flanking paths include transmission through common air ducts between rooms, or doors to the corridor from adjacent rooms. Sound isolation is also influenced by the size of the separating partition between spaces and absorption in the receiving space, and in the case of small spaces by modal behavior of the space and close proximity to surfaces. FIG. 1 Direct (D) and Some Indirect or Flanking Paths (F and Dotted) in a Building ![]() 1.2 The main part of this test method defines procedures and metrics to assess the sound isolation between two rooms or portions thereof in a building separated by a common partition or the apparent sound insulation of the separating partition, including both direct and flanking transmission paths in all cases. Appropriate measures and their single number ratings are the noise reduction (NR) and noise isolation class (NIC) which indicate the isolation with the receiving room furnished as it is during the test, the normalized noise reduction (NNR) and normalized noise isolation class (NNIC) which indicate the isolation expected if the receiving room was a normally furnished living or office space that is at least 25 m3 (especially useful when the test must be done with the receiving room unfurnished), and the apparent transmission loss (ATL) and apparent sound transmission class (ASTC) which indicate the apparent sound insulating properties of a separating partition including both the direct transmission and flanking transmission through the support structure. The measurement of ATL is limited to spaces of at least 25 m3 where modal effects create fewer problems. With the exception of the ATL and ASTC under specified conditions, these procedures in the main part of the test method are only applicable when both room volumes are less than 150 m3. Note 1: The word “partition” in this test method includes all types of walls, floors, or any other boundaries separating two spaces including those that are permanent, operable, or movable. 1.3 The NR and NIC between two locations are always measureable and reportable though conditions present will influence how measurements are performed. With one exception (see 13.5.1), it is required that the NIC always be reported. Restrictions such as minimum room volume or dimensions or maximum room absorption are imposed for all other measures and ratings in this standard. Thus, conditions sometimes exist that will not allow NNR (NNIC) or ATL (ASTC) to be reported. Where a partition between rooms is composed of parts that are constructed differently, or contains an element such as a door, the ATL and ASTC of the individual elements or portions of the partition are not measurable without modifications to the rooms. To evaluate the field performance of a door less than 6 m2 in area, use Test Method E2964. The various metrics are inherently different quantities, so that NIC cannot be used instead of NNIC or ASTC to evaluate compliance with a specification when the specification is written in terms of one of those metrics that cannot be reported with the conditions present. 1.4 Annex A1 provides methods to measure the sound isolation between portions of two rooms in a building separated by a common partition including both direct and flanking paths when at least one of the rooms has a volume of 150 m3 or more. The results are the noise reduction (NR) and noise isolation class (NIC). 1.5 This test method is intended to evaluate the actual acoustical performance between rooms in buildings. Thus, it forbids temporary modifications that influence performance. The measurement methods are useful in diagnostic situations where modifications are made. In such cases reports of results are required to clearly indicate that such modifications were made. 1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.7 The text of this test method references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.8 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
국제분류(ICS)코드 | 91.120.20 : 방음. 진동방지 |
페이지수 | 16 |
Edition | 19a |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ASTM E336-24상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2024-09-01 | 표준 |
2 | ASTM E336-24 REDLINE상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2024-09-01 | 표준 |
3 | ASTM E336-23상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2023-01-01 | 구판 |
4 | ASTM E336-23 REDLINE상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2023-01-01 | 구판 |
5 | ASTM E336-20 REDLINE상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2020-04-01 | 구판 |
6 | ASTM E336-20상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2020-04-01 | 구판 |
7 | ASTM E336-19a상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2019-10-01 | 구판 |
8 | ASTM E336-19a REDLINE상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2019-10-01 | 구판 |
9 | ASTM E336-19 REDLINE상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2019-01-01 | 구판 |
10 | ASTM E336-19상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2019-01-01 | 구판 |
11 | ASTM E336-17a상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2017-11-15 | 구판 |
12 | ASTM E336-17a REDLINE상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2017-11-15 | 구판 |
13 | ASTM E336-17상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2017-07-01 | 구판 |
14 | ASTM E336-16a상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2016-10-01 | 구판 |
15 | ASTM E336-16상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2016-01-01 | 구판 |
16 | ASTM E336-15상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2015-09-01 | 구판 |
17 | ASTM E336-14상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2014-04-15 | 구판 |
18 | ASTM E336-11상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2011-11-01 | 구판 |
19 | ASTM E336-10상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2010-09-01 | 구판 |
20 | ASTM E336-09상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2009-09-01 | 구판 |
21 | ASTM E336-08상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2008-11-01 | 구판 |
22 | ASTM E336-07상세보기 | Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings | 2007-10-01 | 구판 |
23 | ASTM E336-05상세보기 | Standard Test Method for Measurement of Airborne Sound Insulation in Buildings | 2005-04-01 | 구판 |
24 | ASTM E336-97e1상세보기 | Standard Test Method for Measurement of Airborne Sound Insulation in Buildings | 1997-03-10 | 구판 |
25 | ASTM E336-97상세보기 | Standard Test Method for Measurement of Airborne Sound Insulation in Buildings | 1997-03-10 | 구판 |
관련상품
- 관련상품이 존재하지 않습니다.
다른 사람이 함께 구입한 상품
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)