해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
구판
판매
ASTM D1193-06(2018)
Standard Specification for Reagent Water- 발행일 : 2018-03-15
- 발행기관 : ASTM
상세정보
분야 | 11.01 : 물 (Ⅰ) |
---|---|
적용범위 | 1.1 This specification describes the required characteristics of waters deemed suitable for use with the standards under the jurisdiction of ASTM. 1.2 The alphanumeric characters ascribed to water types and grades are specified in the manual, Form and Style for ASTM Standards. These have been assigned in order of historical precedence and should not be taken as an indication of a progression in water purity. 1.3 Four types of waters have been specified, with three additional grades that can be applied to the four types. The grade specifications specifically address contaminants of microbiological origin. 1.4 All applicable ASTM Standards are expected to reference one or more of these reagent water types where reagent water is needed as a component of an analytical measurement process. Where a different water type or grade is needed for an ASTM Standard, it may be added to this Specification through the ASTM Standard revision process. 1.5 Although these water types and associated grades have been defined specifically for use with ASTM Standards, they may be appropriate for other applications. It is the responsibility of the users of this specification to ensure that the selected water types or grades are suitable for their intended use. Historically, reagent water Types I, II, III, and IV have been linked to specific processes for their production. Starting with this revision, these types of waters may be produced with alternate technologies as long as the appropriate constituent specifications are met and that water so produced has been shown to be appropriate for the application where the use of such water is specified. Therefore, the selection of an alternate technology in place of the technology specified in Table 1 should be made taking into account the potential impact of other contaminants such as microorganism and pyrogens. Such contaminants were not necessarily considered by the performance characteristics of the technology previously specified. (A) Type I grade of reagent water shall be prepared by distillation or other equal process, followed by polishing with a mixed bed of ion-exchange materials and a 0.2-µm membrane filter. Feed water to the final polishing step must have a maximum conductivity of 20 µS/cm at 298K (25°C). Type I reagent water may be produced with alternate technologies as long as the appropriate constituent specifications are met and that water so produced has been shown to be appropriate for the application where the use of such water is specified. (B) Type II grade of reagent water shall be prepared by distillation using a still designed to produce a distillate having a conductivity of less than 1.0 µS/cm at 298 K (25°C). Ion exchange, distillation, or reverse osmosis and organic adsorption may be required prior to distillation, if the purity cannot be attained by single distillation. Type II reagent water may be produced with alternate technologies as long as the appropriate constituent specifications are met and that water so produced has been shown to be appropriate for the application where the use of such water is specified. (C) Type III grade of reagent water shall be prepared by distillation, ion exchange, continuous electrodeionization, reverse osmosis, or a combination thereof, followed by polishing with a 0.45-µm membrane filter. Type III reagent water may be produced with alternate technologies as long as the appropriate constituent specifications are met and that water so produced has been shown to be appropriate for the application where the use of such water is specified. (D) Type IV grade of reagent water may be prepared by distillation, ion exchange, continuous electrodeionization, reverse osmosis, electrodialysis, or a combination thereof. Type IV reagent water may be produced with alternate technologies as long as the appropriate constituent specifications are met and that water so produced has been shown to be appropriate for the application where the use of such water is specified. (E) Electrical conductivity at 25°C. (F) Electrical resistivity at 25°C. (G) pH at 25°C, not applicable to higher resistivity waters. (H) Total organic carbon. (I) Sodium. (J) Chloride ion. (K) Heterotrophic bacteria count. (L) Endotoxin in endotoxin units per mL. 1.6 Guidance for applications, the preparation, use and monitoring, storage, handling, distribution, testing of these specified waters and validation of the water purification system is provided in Appendix X1 of this specification. 1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
국제분류(ICS)코드 | 71.040.30 : 화학 시약 및 기준물 |
페이지수 | 6 |
Edition | 06(2018) |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ASTM D1193-24상세보기 | Standard Specification for Reagent Water | 2024-11-01 | 표준 |
2 | ASTM D1193-24 REDLINE상세보기 | Standard Specification for Reagent Water | 2024-11-01 | 표준 |
3 | ASTM D1193-06(2018)상세보기 | Standard Specification for Reagent Water | 2018-03-15 | 구판 |
4 | ASTM D1193-06(2011)상세보기 | Standard Specification for Reagent Water | 2011-05-01 | 구판 |
5 | ASTM D1193-06상세보기 | Standard Specification for Reagent Water | 2006-03-01 | 구판 |
6 | ASTM D1193-99상세보기 | Standard Specification for Reagent Water | 1999-02-10 | 구판 |
7 | ASTM D1193-99e1상세보기 | Standard Specification for Reagent Water | 1999-02-10 | 구판 |
8 | ASTM D1193-91상세보기 | Standard Specification for Reagent Water | 구판 | |
9 | ASTM D1193-77e1상세보기 | Standard Specification for Reagent Water | 구판 | |
10 | ASTM D1193-70상세보기 | Standard Specification For Reagent Water | 구판 |
관련상품
- 관련상품이 존재하지 않습니다.
다른 사람이 함께 구입한 상품
- ASTM D4239-18e1 - Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion
- ASTM E70-07(2015) - Standard Test Method for pH of Aqueous Solutions With the Glass Electrode
- ASTM E691-18 - Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
- ISO 3574:2012 - Cold-reduced carbon steel sheet of commercial and drawing qualities
- ASTM D5865/D5865M-19 - Standard Test Method for Gross Calorific Value of Coal and Coke
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)