CSA C22.2 NO. 62282-3-100:15 (R2020)
Fuel cell technologies - Part 3-100: Stationary fuel cell power systems - Safety (Adopted IEC 62282-3-100:2012, first edition, 2012-02, with Canadian deviations) | Technologies des piles à combustible - Partie 3-100 : Systèmes d'alimentation de piles à combustible fixes - Sécurité (norme IEC 62282-3-100:2012 adoptée, première édition, 2012-02, avec exigences propres au Canada)- 발행일 : 2015-01-01
- 발행기관 : CSA
상세정보
분야 | |
---|---|
적용범위 | Preface This is the first edition of CAN/CSA-C22.2 No. 62282-3-100, Fuel cell technologies - Part 3-100: Stationary fuel cell power systems - Safety, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 62282-3-100 (first edition, 2012-02). For brevity, this Standard will be referred to as "CAN/CSA-C22.2 No. 62282-3-100" throughout. The Canadian deviations are intended to a) correct inaccuracies and inconsistencies with the Canadian Electrical Code, Part I; and b) replace references to IEC Standards with references to CSA Group Standards, where applicable. Scope This part of IEC 62282 applies to stationary packaged, self-contained fuel cell power systems or fuel cell power systems comprised of factory matched packages of integrated systems which generate electricity through electrochemical reactions. This Standard applies to systems ? intended for electrical connection to mains direct, or with a transfer switch, or to a standalone power distribution system; intended to provide AC or DC power; with or without the ability to recover useful heat; intended for operation on the following input fuels a) natural gas and other methane rich gases derived from renewable (biomass) or fossil fuel sources, for example, landfill gas, digester gas, coal mine gas; b) fuels derived from oil refining, for example, diesel, gasoline, kerosene, liquefied petroleum gases such as propane and butane; c) alcohols, esters, ethers, aldehydes, ketones, Fischer-Tropsch liquids and other suitable hydrogen-rich organic compounds derived from renewable (biomass) or fossil fuel sources, for example, methanol, ethanol, di-methyl ether, biodiesel; d) hydrogen, gaseous mixtures containing hydrogen gas, for example, synthesis gas, town gas. This Standard does not cover: ? ?micro fuel cell power systems; ?portable fuel cell power systems; ?propulsion fuel cell power systems. NOTE For special application such as "marine auxiliary power", additional requirements may be given by the relevant marine ship register standard. This Standard is applicable to stationary fuel cell power systems intended for indoor and outdoor commercial, industrial and residential use in non-hazardous (unclassified) areas. This Standard contemplates all significant hazards, hazardous situations and events, with the exception of those associated with environmental compatibility (installation conditions), relevant to fuel cell power systems, when they are used as intended and under the conditions foreseen by the manufacturer. This Standard deals with conditions that can yield hazards on the one hand to persons, and on the other to damage outside the fuel cell system only. Protection against damage to the fuel cell system internals is not addressed in this standard, provided it does not lead to hazards outside the fuel cell system. The requirements of this standard are not intended to constrain innovation. When considering fuels, materials, designs or constructions not specifically dealt with in this standard, these alternatives shall be evaluated as to their ability to yield levels of safety and performance equivalent to those prescribed by this standard. ---------------------------------------------------------------------------------- Pr?face Ce document constitue la premi?re ?dition de la CAN/CSA-C22.2 nº 62282-3-100, Technologies des piles ? combustible - Partie 3-100 : Syst?mes d'alimentation de piles ? combustible fixes - S?curit?. Il s'agit de l'adoption, avec exigences propres au Canada, de la norme CEI (Commission ?lectrotechnique Internationale) 62282-3-100 (premi?re ?dition, 2012-02), qui porte le m?me titre. Par souci de bri?vet?, tout au long de ce document, il sera appel? ?CAN/CSA-C22.2 nº 62282-3-100?. L'objectif des exigences propres au Canada est de : a) corriger les inexactitudes et les incoh?rences avec le Code canadien de l'?lectricit?, Premi?re partie ; et b) remplacer les renvois aux normes de la CEI par les normes du Groupe CSA, le cas ?ch?ant. Domaine d'application La pr?sente partie de la CEI 62282 s'applique aux syst?mes ? piles ? combustible autonomes, assembl?s pour ?tre stationnaires ou aux syst?mes ? piles ? combustible d'un ensemble assembl? en usine de syst?mes int?gr?s qui g?n?rent de l'?lectricit? par r?actions ?lectrochimiques. La pr?sente Norme s'applique aux syst?mes ? ?destin?s ? ?tre connect?s au r?seau ?lectrique directement ou via un interrupteur de transfert, ou destin?s ? ?tre un syst?me de distribution d'?nergie autonome; ?destin?s ? fournir de l'alimentation en courant continu ou alternatif; ?avec ou sans la capacit? de r?cup?rer la chaleur utile; ?destin?s ? fonctionner avec les combustibles suivants en entr?e a) gaz naturel et autres gaz riches en m?thane d?riv?s de sources ? combustible renouvelable (biomasse) ou fossile (le gaz des d?charges, le gaz de digestion, le gaz des mines de charbon, par exemple); b) combustibles d?rivant du raffinage de l'huile (le diesel, l'essence, le k?ros?ne, les gaz de p?trole liqu?fi?s tels que le propane et le butane, par exemple); c) alcools, esters, ?thers, ald?hydes, c?tones, liquides de Fischer-Tropsch et autres composants organiques riches en hydrog?ne appropri?s d?riv?s de sources ? combustible renouvelable (biomasse) ou fossile (le m?thanol, l'?thanol, l'?ther dim?thylique, le biodiesel, par exemple); d) hydrog?ne, m?langes gazeux contenant du gaz hydrog?ne (le gaz de synth?se, le gaz de ville, par exemple). La pr?sente Norme ne couvre pas: ? ?les syst?mes ? micropiles ? combustible; ?les syst?mes ? piles ? combustible portables; ?les syst?mes ? piles ? combustible pour la propulsion. NOTE Pour les applications particuli?res (l'alimentation auxiliaire marine, par exemple), des exigences suppl?mentaires peuvent ?tre donn?es par la norme de registre d'immatriculation des bateaux correspondante. La pr?sente norme s'applique aux syst?mes ? piles ? combustibles stationnaires destin?s ? un usage ? l'int?rieur et ? l'ext?rieur, commercial, industriel ou d'habitation, dans des zones non dangereuses (non class?es). Elle traite de tous les dangers importants, situations et ?v?nements dangereux, ? l'exception de ceux associ?s ? la compatibilit? environnementale (conditions d'installation), relatifs aux syst?mes ? piles ? combustible, lorsqu'ils sont utilis?s comme pr?vu et selon les conditions pr?vues par le fabricant. Cette norme couvre uniquement les conditions qui peuvent g?n?rer d'une part des dangers pour les personnes, et d'autre part des dommages ? l'ext?rieur du syst?me ? piles ? combustible. La protection contre les dommages affectant l'int?rieur des syst?mes ? piles ? combustible n'est pas trait?e dans cette norme, pour autant que ceux-ci ne suscitent pas de dangers ? l'ext?rieur du syst?me ? piles ? combustible. Les exigences de la pr?sente Norme ne sont pas destin?es ? limiter l'innovation. Lorsqu'on consid?re que les combustibles, les mat?riaux, les conceptions ou les constructions ne sont pas sp?cifiquement trait?s par cette norme, leurs caract?ristiques doivent ?tre ?valu?es selon leur aptitude ? fournir des niveaux de s?curit? et de performance ?quivalents ? ceux d?finis dans cette norme.This is the first edition of CAN/CSA-C22.2 No. 62282-3-100, Fuel cell technologies - Part 3-100: Stationary fuel cell power systems - Safety, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 62282-3-100 (first edition, 2012-02). For brevity, this Standard will be referred to as "CAN/CSA-C22.2 No. 62282-3-100" throughout. The Canadian deviations are intended to a) correct inaccuracies and inconsistencies with the Canadian Electrical Code, Part I; and b) replace references to IEC Standards with references to CSA Group Standards, where applicable. ? Scope This part of IEC 62282 applies to stationary packaged, self-contained fuel cell power systems or fuel cell power systems comprised of factory matched packages of integrated systems which generate electricity through electrochemical reactions. This Standard applies to systems ? ?intended for electrical connection to mains direct, or with a transfer switch, or to a standalone power distribution system; ?intended to provide AC or DC power; ?with or without the ability to recover useful heat; ?intended for operation on the following input fuels a) natural gas and other methane rich gases derived from renewable (biomass) or fossil fuel sources, for example, landfill gas, digester gas, coal mine gas; b) fuels derived from oil refining, for example, diesel, gasoline, kerosene, liquefied petroleum gases such as propane and butane; c) alcohols, esters, ethers, aldehydes, ketones, Fischer-Tropsch liquids and other suitable hydrogen-rich organic compounds derived from renewable (biomass) or fossil fuel sources, for example, methanol, ethanol, di-methyl ether, biodiesel; d) hydrogen, gaseous mixtures containing hydrogen gas, for example, synthesis gas, town gas. This Standard does not cover: ?micro fuel cell power systems; ?portable fuel cell power systems; ?propulsion fuel cell power systems. NOTE For special application such as "marine auxiliary power", additional requirements may be given by the relevant marine ship register standard. This Standard is applicable to stationary fuel cell power systems intended for indoor and outdoor commercial, industrial and residential use in non-hazardous (unclassified) areas. This Standard contemplates all significant hazards, hazardous situations and events, with the exception of those associated with environmental compatibility (installation conditions), relevant to fuel cell power systems, when they are used as intended and under the conditions foreseen by the manufacturer. This Standard deals with conditions that can yield hazards on the one hand to persons, and on the other to damage outside the fuel cell system only. Protection against damage to the fuel cell system internals is not addressed in this standard, provided it does not lead to hazards outside the fuel cell system. The requirements of this standard are not intended to constrain innovation. When considering fuels, materials, designs or constructions not specifically dealt with in this standard, these alternatives shall be evaluated as to their ability to yield levels of safety and performance equivalent to those prescribed by this standard. ---------------------------------------------------------------------------------- Pr?face Ce document constitue la premi?re ?dition de la CAN/CSA-C22.2 nº 62282-3-100, Technologies des piles ? combustible - Partie 3-100 : Syst?mes d'alimentation de piles ? combustible fixes - S?curit?. Il s'agit de l'adoption, avec exigences propres au Canada, de la norme CEI (Commission ?lectrotechnique Internationale) 62282-3-100 (premi?re ?dition, 2012-02), qui porte le m?me titre. Par souci de bri?vet?, tout au long de ce document, il sera appel? ?CAN/CSA-C22.2 nº 62282-3-100?. L'objectif des exigences propres au Canada est de : a) corriger les inexactitudes et les incoh?rences avec le Code canadien de l'?lectricit?, Premi?re partie ; et b) remplacer les renvois aux normes de la CEI par les normes du Groupe CSA, le cas ?ch?ant. Domaine d'application La pr?sente partie de la CEI 62282 s'applique aux syst?mes ? piles ? combustible autonomes, assembl?s pour ?tre stationnaires ou aux syst?mes ? piles ? combustible d'un ensemble assembl? en usine de syst?mes int?gr?s qui g?n?rent de l'?lectricit? par r?actions ?lectrochimiques. La pr?sente Norme s'applique aux syst?mes ? ?destin?s ? ?tre connect?s au r?seau ?lectrique directement ou via un interrupteur de transfert, ou destin?s ? ?tre un syst?me de distribution d'?nergie autonome; ?destin?s ? fournir de l'alimentation en courant continu ou alternatif; ?avec ou sans la capacit? de r?cup?rer la chaleur utile; ?destin?s ? fonctionner avec les combustibles suivants en entr?e a) gaz naturel et autres gaz riches en m?thane d?riv?s de sources ? combustible renouvelable (biomasse) ou fossile (le gaz des d?charges, le gaz de digestion, le gaz des mines de charbon, par exemple); b) combustibles d?rivant du raffinage de l'huile (le diesel, l'essence, le k?ros?ne, les gaz de p?trole liqu?fi?s tels que le propane et le butane, par exemple); c) alcools, esters, ?thers, ald?hydes, c?tones, liquides de Fischer-Tropsch et autres composants organiques riches en hydrog?ne appropri?s d?riv?s de sources ? combustible renouvelable (biomasse) ou fossile (le m?thanol, l'?thanol, l'?ther dim?thylique, le biodiesel, par exemple); d) hydrog?ne, m?langes gazeux contenant du gaz hydrog?ne (le gaz de synth?se, le gaz de ville, par exemple). La pr?sente Norme ne couvre pas: ? ?les syst?mes ? micropiles ? combustible; ?les syst?mes ? piles ? combustible portables; ?les syst?mes ? piles ? combustible pour la propulsion. NOTE Pour les applications particuli?res (l'alimentation auxiliaire marine, par exemple), des exigences suppl?mentaires peuvent ?tre donn?es par la norme de registre d'immatriculation des bateaux correspondante. La pr?sente norme s'applique aux syst?mes ? piles ? combustibles stationnaires destin?s ? un usage ? l'int?rieur et ? l'ext?rieur, commercial, industriel ou d'habitation, dans des zones non dangereuses (non class?es). Elle traite de tous les dangers importants, situations et ?v?nements dangereux, ? l'exception de ceux associ?s ? la compatibilit? environnementale (conditions d'installation), relatifs aux syst?mes ? piles ? combustible, lorsqu'ils sont utilis?s comme pr?vu et selon les conditions pr?vues par le fabricant. Cette norme couvre uniquement les conditions qui peuvent g?n?rer d'une part des dangers pour les personnes, et d'autre part des dommages ? l'ext?rieur du syst?me ? piles ? combustible. La protection contre les dommages affectant l'int?rieur des syst?mes ? piles ? combustible n'est pas trait?e dans cette norme, pour autant que ceux-ci ne suscitent pas de dangers ? l'ext?rieur du syst?me ? piles ? combustible. Les exigences de la pr?sente Norme ne sont pas destin?es ? limiter l'innovation. Lorsqu'on consid?re que les combustibles, les mat?riaux, les conceptions ou les constructions ne sont pas sp?cifiquement trait?s par cette norme, leurs caract?ristiques doivent ?tre ?valu?es selon leur aptitude ? fournir des niveaux de s?curit? et de performance ?quivalents ? ceux d?finis dans cette norme. |
국제분류(ICS)코드 | |
페이지수 | 198 |
Edition |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | CSA C22.2 NO. 62282-3-100:15 (R2020)상세보기 | Fuel cell technologies - Part 3-100: Stationary fuel cell power systems - Safety (Adopted IEC 62282-3-100:2012, first edition, 2012-02, with Canadian deviations) | Technologies des piles à combustible - Partie 3-100 : Systèmes d'alimentation de piles à combustible fixes - Sécurité (norme IEC 62282-3-100:2012 adoptée, première édition, 2012-02, avec exigences propres au Canada) | 2015-01-01 | 폐지 |
다른 사람이 함께 구입한 상품
- CSA C22.2 NO. 232:17 (R2021) - Optical fiber cables
- C22.1-18 - Canadian Electrical Code, Part I (24th Edition), Safety Standard for Electrical Installations
- CSA C653:18 (R2024) - Photometric performance of roadway and street lighting luminaires
- CSA C22.2 NO. 291:19 - Bare and covered ferrules (Binational standard with UL 486F)
- CSA C22.2 NO. 62368-1:19 - Audio/video, information and communication technology equipment - Part 1: Safety requirements (Binational standard with UL 62368-1)
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)