IEC 60364-5-56:2009
Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services- 발행일 : 2009-07-30
- 발행기관 : IEC
- 대체표준 : IEC 60364-5-56:2018
상세정보
분야 | TC 64 : Electrical installations and protection against electric shock |
---|---|
적용범위 | IEC 60364-5-56:2009 covers general requirements for safety services, selection and erection of electrical supply systems for safety services and electrical safety sources. Standby electrical supply systems are outside the scope of this part. This part does not apply to installations in hazardous areas (BE3), for which requirements are given in IEC 60079-14. This second edition of IEC 60364-5-56 comes about as a result of changes to Clause 556, Safety services, of IEC 60364-5-55 (2001), as modified by its amendment 1 (2001). It replaces Clause 556 of IEC 60364-5-55:2001. Clause 556 is to be withdrawn at the time of publication of this new Part 56. The main changes with regard to the previous edition are listed below: 1) Many more definitions are included, e.g. response time, central power supply system, low power supply system, preferential circuit and escape route. 2) Automatic supplies are now classified according to the maximum changeover times, for example a supply classified as short break means an automatic supply is available within 0,5 s. 3) Safety sources that can operate in parallel are specifically recognized in 560.6.9. 4) Requirements are now given for batteries used for safety sources for central and low power supply sources. 5) Drawings are now required, such as a single-line diagram, drawings showing the location of equipment and a list of equipment permanently connected to the safety power supply. 6) Operating instructions are now required. 7) Detailed requirements are now given for emergency escape lighting applications, direct current circuits and fire protection applications. 8) Additional requirements for initial verification and periodic inspection and testing are now included in the standard. 9) Two annexes are now included (Annex A and Annex B) giving guidance for emergency lighting and guidance for fire protection equipment, respectively. |
국제분류(ICS)코드 | 91.140.50 : 전기 공급 체계 |
페이지수 | 38 |
Edition | 2.0 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 60364-5-56:2018상세보기 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services | 2018-11-02 | 표준 |
2 | IEC 60364-5-56:2018 RLV상세보기 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services | 2018-11-02 | 표준 |
3 | IEC 60364-5-56:2009상세보기 | Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services | 2009-07-30 | 구판 |
4 | IEC 60364-5-56:1980+AMD1:1998 CSV상세보기 | Electrical installations of buildings - Part 5: Selection and erection of electrical equipment - Chapter 56: Safety services | 1999-01-21 | 폐지(대체) |
5 | IEC 60364-5-56:1980/AMD1:1998상세보기 | Amendment 1 - Electrical installations of buildings. Part 5: Selection and erection of electrical equipment. Chapter 56: Safety services | 1998-11-06 | 폐지(대체) |
6 | IEC 60364-5-56:1980상세보기 | Electrical installations of buildings. Part 5: Selection and erection of electrical equipment. Chapter 56: Safety services | 1980-01-01 | 폐지(대체) |
관련상품
- IEC 60364-2:1970 - Electrical installations of buildings - Part 2: Fundamental principles
- IEC 60364-3-1:1973 - Electrical installations of buildings - Part 3: General requirements for installations - Chapter 1: Measures for protection for safety. Sections One to Three
- IEC 60364-4-473:1977 - Electrical installations of buildings. Part 4: Protection for safety. Chapter 47: Application of protective measures for safety. Section 473: Measures of protection against overcurrent
- IEC 60364-5-56:1980 - Electrical installations of buildings. Part 5: Selection and erection of electrical equipment. Chapter 56: Safety services
- IEC 60364-4-46:1981 - Electrical installations of buildings. Part 4: Protection for safety. Chapter 46: Isolation and switching
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)