QUICK

TOP

해외표준 상세정보

관심표준 등록 : 표준업데이트 시 알림서비스

제공형태 더보기
  • 표준

    판매

    IEC 61331-1:2014

    Protective devices against diagnostic medical X-radiation - Part 1: Determination of attenuation properties of materials
    • 발행일 : 2014-05-07
    • 발행기관 : IEC
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어/불어]PDF 269,500원

    • [영어/불어]PRINT 269,500원

상세정보

분야 TC 62/SC 62B : Medical imaging equipment, software, and systems
적용범위 IEC 61331:2014 applies to materials in sheet form used for the manufacturing of protective devices against X-radiation of radiation qualities generated with X-ray tube voltages up to 400 kV and gamma radiation emitted by radionuclides with photon energies up to 1,3 MeV. This Part 1 is not intended to be applied to protective devices when these are to be checked for the presence of their attenuation properties before and after periods of use. This Part 1 specifies the methods of determining and indicating the attenuation properties of the materials. The attenuation properties are given in terms of:
- attenuation ratio;
- build-up factor; and
- attenuation equivalent together with, as appropriate, an indication of homogeneity and mass per unit area. Ways of stating values of attenuation properties in compliance with this part of the International Standard are included. Excluded from the scope of this International Standard are the methods for periodical checks of protective devices, particularly of protective clothing, the methods of determining attenuation by layers in the radiation beam, and the methods of determining attenuation for purposes of protection against ionizing radiation provided by walls and other parts of an installation. This second edition cancels and replaces the first edition of IEC 61331-1, published in 1994. It constitutes a technical revision. This second edition has been adapted to apply to the present technology. In particular, this second edition is consistently applicable to lead- and non-lead-containing materials. The essential changes and extensions are:
- the extension of the scope to cover photon-emitting radionuclides;
- improved methods to determine the attenuation ratio;
- the addition of the so-called inverse broad beam condition;
- the addition of a method to calculate the attenuation ratio of photon-emitting radionuclides;
- the definition of new standard X- and gamma radiation qualities used for testing;
- the addition of the so-called lead equivalent class; and
- tables of attenuation ratios, build-up factors and first half-value layers for the standard radiation qualities filtered with different thicknesses of lead.
국제분류(ICS)코드 11.040.50 : 방사선 및 기타 진단 기기
페이지수 50
Edition 2.0

이력정보

No. 표준번호 표준명 발행일 상태
1 IEC 61331-1:2014상세보기 Protective devices against diagnostic medical X-radiation - Part 1: Determination of attenuation properties of materials 2014-05-07 표준
2 IEC 61331-1:1994상세보기 Protective devices against diagnostic medical X-radiation - Part 1: Determination of attenuation properties of materials 1994-10-21 구판

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)