IEC TR 61850-80-5:2024
Communication networks and systems for power utility automation - Part 80-5: Guideline for mapping information between IEC 61850 and IEC 61158-15- 발행일 : 2024-02-09
- 발행기관 : IEC
상세정보
분야 | TC 57 : Power systems management and associated information exchange |
---|---|
적용범위 | IEC TR 61850-80-5:2024, which is a Technical Report, specifies the mapping rules for building and configuring a system using both IEC 61850 and IEC 61158-6 (Industrial communication networks - Fieldbus specification, CPF Type 15, Modbus) protocols by utilizing gateways between IEC 61850 and IEC 61158-6 IEDs / subsystems. The objective is to enable operational run-time data exchange among these IEDs / subsystems, and to automate the configuration of a gateway as much as possible. Please note that for the purposes of this document, "Modbus" is used to represent both serial Modbus (Modbus RTU) and IEC 61158-6 (Modbus TCP). Within the capability of each protocol, some configuration attributes (IEC 61850-7-3:2010+AMD1:2020 attributes with functional constraint CF) are also mapped in addition to the operational real-time data. The rules specified in this document are based on the published standards and do not make any proposed changes to IEC 61850 or 61158-6. This standard does not specify any rules for an IEC 61850 IED to directly communicate with a Modbus IED and vice versa, except through a gateway. This document does not mandate which data items that a particular IED shall support, regardless of whether the implementation uses Modbus or IEC 61850. Instead this document provides rules specifying how a gateway maps any given data item from one protocol to the other, given that the data item is already available and is transmitted using one of the protocols. Similarly, this document does not mandate which mapping rules a given gateway shall support. When this document is republished as a Technical Specification, conformance requirements will be identified. This document recognizes that there will be situations in which a user will require that a gateway perform non-standard protocol mappings. Non-standard mappings are outside the scope of this document. This document also recognizes that gateways typically manipulate the data passing through them in a variety of ways. Some of these functions include alarm trigger grouping, data suppression, interlocking and command blocking. Conformance to this document does not preclude a gateway from performing such functions, even though this document primarily specifies "straight through" mapping of Modbus data to IEC 61850-7-3:2010+AMD1:2020 data. Subclause 7.4 of this document describes how some of these functions may be specified to a gateway by a mapping tool using equation notation in XML. However, some of these functions may be too complex for a mapping tool to specify in an automated manner. The mapping architecture for the exchange of the run-time information consists of four parts: 1) Conceptual architecture of a gateway and associated use case 2) Mapping of the information model (Assign semantic to the Modbus data) 3) Mapping of the data (which is in fact part of the information model) 4) Mapping of the services (out of scope for this document) |
국제분류(ICS)코드 | 33.200 : 원격 제어. 원격 측정 |
페이지수 | 47 |
Edition | 1.0 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC TR 61850-80-5:2024상세보기 | Communication networks and systems for power utility automation - Part 80-5: Guideline for mapping information between IEC 61850 and IEC 61158-15 | 2024-02-09 | 표준 |
관련상품
- IEC 61850-9-1:2003 - Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link
- IEC 61850-6:2009 - Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs
- IEC TR 61850-90-1:2010 - Communication networks and systems for power utility automation - Part 90-1: Use of IEC 61850 for the communication between substations
- IEC 61850-7-4:2010 - Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes
- IEC 61850-7-2:2010 - Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI)
다른 사람이 함께 구입한 상품
- IEC TR 61850-7-510:2021 - Communication networks and systems for power utility automation - Part 7-510: Basic communication structure - Hydroelectric power plants, steam and gas turbines - Modelling concepts and guidelines
- IEC TR 61850-90-5:2012 - Communication networks and systems for power utility automation - Part 90-5: Use of IEC 61850 to transmit synchrophasor information according to IEEE C37.118
- IEC TR 61850-90-8:2016 - Communication networks and systems for power utility automation - Part 90-8: Object model for E-mobility
- IEC TR 61850-90-4:2020 - Communication networks and systems for power utility automation - Part 90-4: Network engineering guidelines
- IEC TR 61850-10-3:2022 - Communication networks and systems for power utility automation - Part 10-3: Functional testing of IEC 61850 systems
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)