해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
표준
판매
IEC TR 61850-7-6:2024
Communication networks and systems for power utility automation - Part 7-6: Guideline for definition of Basic Application Profiles (BAPs) using IEC 61850- 발행일 : 2024-12-06
- 발행기관 : IEC
상세정보
분야 | TC 57 : Power systems management and associated information exchange |
---|---|
적용범위 | IEC TR 61850-7-6:2024, which is a Technical Report, is focused on building application / function profiles and specifies a methodology to define Basic Application Profiles (BAPs), in textual documents (edition 1, 2019) or in a machine processable SCL format (current edition). These Basic Application Profiles provide a framework for interoperable interaction within or between typical substation automation functions. BAPs are intended to define a subset of features of IEC 61850 in order to facilitate interoperability in a modular way in practical applications. It is the intention of this document to provide a common and generic way to describe the functional behavior of a specific application function in the domain of power utility automation systems as a common denominator of various possible interpretations/implementations of using IEC 61850. The guidelines in this document are based on the functional definitions of: • IEC 61850-5, Communication requirements for functions and device models, which gives a comprehensive overview of all application functions needed in a state-of-the-art substation automation implementation. • IEC TR 61850-7-500, Basic information and communication structure – Use of logical nodes for modelling application functions and related concepts and guidelines for substations, which illustrates and explains application functions for the substation/protection domain of Logical Nodes in modelling simple and complex functions, to improve common understanding in modelling and data exchange, and finally to lead to interoperable implementations. • IEC TR 61850-90-3, Using IEC 61850 for condition monitoring diagnosis and analysis, which gives use cases and data modelling for condition monitoring diagnosis and analysis functions for substation and power grid facilities. • IEC TR 61850-90-30, IEC 61850 Function Modelling in SCL, which describes extensions of the SCL Substation/Process Section allowing to create a comprehensive, IED and hardware independent specification of an IEC 61850 based power system. This document does not describe the applications and respective implementation requirements; the focus is on their typical information exchange including data and communication services and engineering conventions. This second edition cancels and replaces the first edition published in 2019. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) New Clause 5 added to describe the way to express Basic Application Profile in SCL files; b) New Annex F and Annex G added to list specific use cases and roles of the Concept Definition Tool. |
국제분류(ICS)코드 | 33.200 : 원격 제어. 원격 측정 |
페이지수 | 144 |
Edition | 2.0 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC TR 61850-7-6:2024상세보기 | Communication networks and systems for power utility automation - Part 7-6: Guideline for definition of Basic Application Profiles (BAPs) using IEC 61850 | 2024-12-06 | 표준 |
2 | IEC TR 61850-7-6:2019상세보기 | Communication networks and systems for power utility automation - Part 7-6: Guideline for definition of Basic Application Profiles (BAPs) using IEC 61850 | 2019-01-16 | 구판 |
관련상품
- IEC 61850-9-1:2003 - Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link
- IEC 61850-6:2009 - Communication networks and systems for power utility automation - Part 6: Configuration description language for communication in electrical substations related to IEDs
- IEC TR 61850-90-1:2010 - Communication networks and systems for power utility automation - Part 90-1: Use of IEC 61850 for the communication between substations
- IEC 61850-7-4:2010 - Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes
- IEC 61850-7-2:2010 - Communication networks and systems for power utility automation - Part 7-2: Basic information and communication structure - Abstract communication service interface (ACSI)
다른 사람이 함께 구입한 상품
- KS C IEC 61850-7-2 - 전력 유틸리티 자동화를 위한 통신 네트워크 및 시스템 — 제7-2부: 기본 정보와 통신 구조 — 추상 통신서비스 인터페이스(ACSI)
- IEC TR 61850-7-510:2021 - Communication networks and systems for power utility automation - Part 7-510: Basic communication structure - Hydroelectric power plants, steam and gas turbines - Modelling concepts and guidelines
- IEC 61000-6-4:2018 - Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
- KS C IEC TS 61850-7-7 - 전력 유틸리티 자동화를 위한 통신 네트워크 및 시스템 — 제7-7부: 툴을 위한 KS C IEC 61850 관련 데이터 모델의 기계 처리 가능 포맷
- IEC TR 61850-90-22:2024 - Communication networks and systems for power utility automation – Part 90-22: SCD based substation network automated management with visualization and supervision support
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)