IEC 60664-3:2003
Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution- 발행일 : 2003-02-17
- 발행기관 : IEC
- 대체표준 : IEC 60664-3:2016
상세정보
분야 | TC 109 : Insulation co-ordination for low-voltage equipment |
---|---|
적용범위 | Applies to assemblies protected against pollution by the use of coating, potting or moulding, thus allowing a reduction of clearance and creepage distances as described in Part 1 or Part 5. This standard describes the requirements and test procedures for two methods of protection: - type 1 protection improves the microenvironment of the parts under the protection; - type 2 protection is considered to be similar to solid insulation. This standard also applies to all kinds of protected printed boards, including the surface of inner layers of multi-layer boards, substrates and similarly protected assemblies. In the case of multi-layer printed boards, the distances through an inner layer are covered by the requirements for solid insulation in Part 1. This standard refers only to permanent protection. It does not cover assemblies that are subjected to mechanical adjustment or repair. The principles of this standard are applicable to functional, basic, supplementary and reinforced insulation. Has the status of a basic safety publication in accirdance with IEC Guide 104. The major changes made during the revision of IEC 60664-3 were the following: - Part 3 has been exactly aligned with Part 1 (including amendments 1 and 2). It has been made clear that Part 3 can only be used as a whole document together with Part 1 of IEC 60664. - The scope of Part 3 has been greatly extended including now also potting and moulding and similar procedures providing protection against pollution. The standard also applies to all kinds of coated printed boards including the surface of inner-layers of multi-layer boards, substrates and similar protected assemblies. The distances through an inner layer of multi-layer boards however are covered by the requirements for solid insulation in Part 1. - The difference between the two types of protection has been clarified. Type 1 (formerly type A) protection leads to a reduction of the pollution degree present beyond the protection to pollution degree 1. Type 2 (formerly type B) protection introduces protection systems which can be considered similar to solid insulation. Consequently the dimensioning and test requirements have been aligned more correctly. - The area of application has been extended including now functional, basic, supplementary and reinforced insulation. - Type 1 and type 2 protection now can both be used under the conditions of pollution degree 3 (formerly only type B). - Not only type 2 protection but also type 1 protection requires that between two conductive parts 100 % of the distance across the spacing shall be covered by the protection. - For type 2 protection minimum distances have been introduced. In any case the spacings shall not be lower than the minimum value of 10 µm. - Also the new Part 5 of IEC 60664 is referred to. - The tests follow much more closely the different requirements for type 1 and type 2 protection. The protected assembly shall withstand the electrical tests for solid insulation in 4.1.2 of IEC 60664-1. For type 1 protection, the partial discharge test is not applicable. For type 2 protection, the partial discharge test is required. The required partial discharge extinction voltage and the test method are specified in 4.1.2.4 of IEC 60664-1. - The requirements for the test specimen have been aligned with the extended scope. - The tests for the "adhesion of coating" and the "scratch resistance test" have been updated. |
국제분류(ICS)코드 | 29.080.30 : 절연 시스템 |
페이지수 | 47 |
Edition | 2.0 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 60664-3:2016 RLV상세보기 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution | 2016-11-04 | 표준 |
2 | IEC 60664-3:2016상세보기 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution | 2016-11-04 | 표준 |
3 | IEC 60664-3:2003/AMD1:2010/COR1:2010상세보기 | Corrigendum 1 to amendment 1 - Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution | 2010-11-29 | 구판 |
4 | IEC 60664-3:2003+AMD1:2010 CSV상세보기 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution | 2010-08-23 | 구판 |
5 | IEC 60664-3:2003/AMD1:2010상세보기 | Amendment 1 - Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution | 2010-05-19 | 구판 |
6 | IEC 60664-3:2003상세보기 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution | 2003-02-17 | 구판 |
7 | IEC 60664-3:1992상세보기 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coatings to achieve insulation coordination of printed board assemblies | 1992-10-13 | 구판 |
관련상품
- IEC TR 60664-2-2:2002 - Insulation coordination for equipment within low-voltage systems - Part 2-2: Interface considerations - Application guide
- IEC 60664-4:2005 - Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress
- IEC 60664-5:2007 - Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm
- IEC TR 60664-2-1:2011 - Insulation coordination for equipment within low-voltage systems - Part 2-1: Application guide - Explanation of the application of the IEC 60664 series, dimensioning examples and dielectric testing
- IEC TR 60664-2-1:2011/COR1:2011 - Corrigendum 1 - Insulation coordination for equipment within low-voltage systems - Part 2-1: Application guide - Explanation of the application of the IEC 60664 series, dimensioning examples and dielectric testing
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)