해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
표준
판매
IEC 60664-3:2016 RLV
Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution- 발행일 : 2016-11-04
- 발행기관 : IEC
-
레드라인이란?
* RLV (Red-Line Version) : 구판과 최신판의 변경 사항을 빨간펜으로 표시해서 비교할 수 있게 만든 버전
* CMV (Commented version) : 표준의 개정 시 변경 부분(레드라인)에 대한 코멘트(메모)가 추가된 버전
* RLV 혹은 CMV를 구입하시면 최신판(Final version)은 별도로 구매하지 않아도 됩니다.
상세정보
분야 | |
---|---|
적용범위 | IEC 60664-3:2016 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 60664-3:2016 applies to assemblies protected against pollution by the use of coating, potting or moulding, thus allowing a reduction of clearance and creepage distances as described in IEC 60664-1. This document describes the requirements and test procedures for two methods of protection: - type 1 protection improves the microenvironment of the parts under the protection; - type 2 protection is considered to be similar to solid insulation. This edition includes the following significant technical changes with respect to the previous edition: a) information added concerning interpolation; b) provided scratch test is only for type 2 protection; c) renumbered the scratch test to follow the visual examination test, since it makes more sense there; d) separated the tables under what is now called Annex A, to make them clearer. |
국제분류(ICS)코드 | 29.080.30 : 절연 시스템 |
페이지수 | 77 |
Edition | 3.0 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 60664-3:2016 RLV상세보기 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution | 2016-11-04 | 표준 |
2 | IEC 60664-3:2016상세보기 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution | 2016-11-04 | 표준 |
3 | IEC 60664-3:2003/AMD1:2010/COR1:2010상세보기 | Corrigendum 1 to amendment 1 - Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution | 2010-11-29 | 구판 |
4 | IEC 60664-3:2003+AMD1:2010 CSV상세보기 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution | 2010-08-23 | 구판 |
5 | IEC 60664-3:2003/AMD1:2010상세보기 | Amendment 1 - Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution | 2010-05-19 | 구판 |
6 | IEC 60664-3:2003상세보기 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution | 2003-02-17 | 구판 |
7 | IEC 60664-3:1992상세보기 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coatings to achieve insulation coordination of printed board assemblies | 1992-10-13 | 구판 |
관련상품
- IEC TR 60664-2-2:2002 - Insulation coordination for equipment within low-voltage systems - Part 2-2: Interface considerations - Application guide
- IEC 60664-4:2005 - Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress
- IEC 60664-5:2007 - Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm
- IEC TR 60664-2-1:2011 - Insulation coordination for equipment within low-voltage systems - Part 2-1: Application guide - Explanation of the application of the IEC 60664 series, dimensioning examples and dielectric testing
- IEC TR 60664-2-1:2011/COR1:2011 - Corrigendum 1 - Insulation coordination for equipment within low-voltage systems - Part 2-1: Application guide - Explanation of the application of the IEC 60664 series, dimensioning examples and dielectric testing
다른 사람이 함께 구입한 상품
- IEC 61850-7-1:2011+AMD1:2020 CSV - Communication networks and systems for power utility automation - Part 7-1: Basic communication structure - Principles and models
- IEC TR 61000-3-7:2008 - Electromagnetic compatibility (EMC) - Part 3-7: Limits - Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems
- IEC 62271-103:2021 - High-voltage switchgear and controlgear - Part 103: Alternating current switches for rated voltages above 1 kV up to and including 52 kV
- IEC 61000-4-5:2014+AMD1:2017 CSV - Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
- IEC GUIDE 107:2014 - Electromagnetic compatibility - Guide to the drafting of electromagnetic compatibility publications
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)