해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
구판
판매
IEC 61010-2-032:2012
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement- 발행일 : 2012-09-26
- 발행기관 : IEC
- 대체표준 : IEC 61010-2-032:2019
상세정보
분야 | TC 66 : Safety of measuring, control and laboratory equipment |
---|---|
적용범위 | IEC 61010-2-032:2012 specifies safety requirements for HAND-HELD and hand-manipulated current sensors described below. These current sensors are for measuring, detecting or injecting current, or indicating current waveforms on circuits without physically opening the current path of the circuit being measured. They may be stand-alone current sensors or accessories to other equipment or parts of combined equipment (see Figure 101). These include measurement circuits which are part of electrical test and measurement equipment, laboratory equipment, or process control equipment. The existence of these current sensors and circuits in equipment requires additional protective means between the current sensor, the circuit and an OPERATOR. This third edition cancels and replaces the second edition published in 2002. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) A new Type D current sensor has been defined. b) The terminology for MEASUREMENT CATEGORY I has changed. In this Part 2-032, it is termed "not RATED for measurements within MEASUREMENT CATEGORIES II, III, or IV". c) Requirements for markings of measuring circuit TERMINALS and JAWS have been modified. d) CLEARANCES and CREEPAGE DISTANCES have been added for unmated measuring circuit TERMINALS. e) Requirements have been added for specialized measuring circuit TERMINALS. f) The pull test for endcaps of flexible current sensors has been revised. g) Requirements for output circuit leads have been revised. h) Requirements have been added for temperature limits and resistance to heat to prevent thermal HAZARDS from eddy currents and high currents. i) Requirements for circuits or components used as TRANSIENT OVERVOLTAGE limiting devices have been revised. j) Requirements have been added for low battery indication. k) Requirements have been revised and added pertaining to REASONABLY FORESEEABLE MISUSE of measuring circuits, including usage of the current sensor in a manner that might cause arc flash. l) Requirements for MAINS voltage measuring circuits have been added. m) Requirements to prevent HAZARDs from short-circuits have been revised and located in a new Clause 102. n) ROUTINE TESTS have been modified. o) Insulation requirements for measuring circuits have been primarily located in Annex K. p) Annex AA has been added to describe the characteristics of MEASUREMENT CATEGORIES. q) Annex BB has been added to describe HAZARDS that may be encountered when using measuring circuits. This publication is to be read in conjunction with IEC 61010-1:2010. |
국제분류(ICS)코드 | 19.080 : 전기 및 전자 시험 및 측정기구 |
페이지수 | 99 |
Edition | 3.0 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 61010-2-032:2023상세보기 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2023-09-20 | 표준 |
2 | IEC 61010-2-032:2019/COR1:2020상세보기 | Corrigendum 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2020-02-26 | 구판 |
3 | IEC 61010-2-032:2019상세보기 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2019-06-21 | 구판 |
4 | IEC 61010-2-032:2019 RLV상세보기 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2019-06-21 | 구판 |
5 | IEC 61010-2-032:2012상세보기 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2012-09-26 | 구판 |
6 | IEC 61010-2-032:2002상세보기 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2002-09-30 | 구판 |
7 | IEC 61010-2-032:1994상세보기 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test | 1994-12-15 | 구판 |
관련상품
- IEC 61010-2-031:1993 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-031: Particular requirements for hand-held probe assemblies for electrical measurement and test
- IEC 61010-2-041:1995 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-041: Particular requirements for autoclaves using steam for the treatment of medical materials, and for laboratory processes
- IEC 61010-2-043:1997 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-043: Particular requirements for dry heat sterilizers using either hot air or hot inert gas for the treatment of medical materials, and for laboratory processes
- IEC 61010-2-042:1997 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-042: Particular requirements for autoclaves and sterilizers using toxic gas for the treatment of medical materials, and for laboratory processes
- IEC TR 61010-3-010:1999 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-010: Conformity verification report for IEC 61010-2-010, Particular requirements for laboratory equipment for the heating of materials
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)