IEC 61010-2-032:2019
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement- 발행일 : 2019-06-21
- 발행기관 : IEC
- 대체표준 : IEC 61010-2-032:2023
상세정보
분야 | TC 66 : Safety of measuring, control and laboratory equipment |
---|---|
적용범위 | IEC 61010-2-032:2019 specifies safety requirements for hand-held and hand-manipulated current sensors described below. These current sensors are for measuring, detecting or injecting current, or indicating current waveforms on circuits without physically opening the current path of the circuit being measured. They can be stand-alone current sensors or accessories to other equipment or parts of combined equipment (see Figure 101). These include measurement circuits which are part of electrical test and measurement equipment, laboratory equipment, or process control equipment. These current sensors and circuits need additional protective means between the current sensor, the circuit and an operator. This fourth edition cancels and replaces the third edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - It has been indicated that current sensors used as fixed equipment are not within the scope of this document. - Fork-style current sensors have been added. - Requirements from Part 2-033 applicable to clamp multimeters that have a primary purpose of measuring voltage on live mains have been included in the new normative Annex EE. - Clearances and creepage distances for measuring circuit terminals exceeding 1 000 V a.c. or 1 414 V d.c. and for wet locations have been specified. - Reduced creepage distances are allowed to be according to material group I for all insulating materials. - Requirements for input/output circuits of Type A, Type B and Type C current sensors have been detailed in 6.9.102. - Requirements for output circuit leads have been modified. - The Jaw impact test has been limited to the front of the jaws. - The abrasion test for cords of flexible current sensors has been removed and replaced by a pressure test at high temperature. - The voltage source for testing overvoltage limiting components or circuits may be limited to 400 V. - Reference to IEC 61010-031 for probe assemblies has been added. - Requirements for the prevention of transient overvoltages for mains voltage measuring circuits have been added. - Requirements for measuring circuits from 1 000 V to 3 000 V have been added. - An informative Annex CC about the dimensions of banana terminals has been added. - A flowchart for insulation according to the type of circuit has been added in a new Annex DD. The contents of the corrigendum of February 2020 have been included in this copy. |
국제분류(ICS)코드 | 19.080 : 전기 및 전자 시험 및 측정기구 |
페이지수 | 124 |
Edition | 4.0 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 61010-2-032:2023상세보기 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2023-09-20 | 표준 |
2 | IEC 61010-2-032:2019/COR1:2020상세보기 | Corrigendum 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2020-02-26 | 구판 |
3 | IEC 61010-2-032:2019상세보기 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2019-06-21 | 구판 |
4 | IEC 61010-2-032:2019 RLV상세보기 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2019-06-21 | 구판 |
5 | IEC 61010-2-032:2012상세보기 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2012-09-26 | 구판 |
6 | IEC 61010-2-032:2002상세보기 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2002-09-30 | 구판 |
7 | IEC 61010-2-032:1994상세보기 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test | 1994-12-15 | 구판 |
관련상품
- IEC 61010-2-031:1993 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-031: Particular requirements for hand-held probe assemblies for electrical measurement and test
- IEC 61010-2-041:1995 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-041: Particular requirements for autoclaves using steam for the treatment of medical materials, and for laboratory processes
- IEC 61010-2-043:1997 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-043: Particular requirements for dry heat sterilizers using either hot air or hot inert gas for the treatment of medical materials, and for laboratory processes
- IEC 61010-2-042:1997 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-042: Particular requirements for autoclaves and sterilizers using toxic gas for the treatment of medical materials, and for laboratory processes
- IEC TR 61010-3-010:1999 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-010: Conformity verification report for IEC 61010-2-010, Particular requirements for laboratory equipment for the heating of materials
다른 사람이 함께 구입한 상품
- 함께 구입한 상품이 존재하지 않습니다.
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)