IEC 61010-2-032:2023
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement- 발행일 : 2023-09-20
- 발행기관 : IEC
상세정보
분야 | TC 66 : Safety of measuring, control and laboratory equipment |
---|---|
적용범위 | IEC 61010-2-032:2023 specifies safety requirements for hand-held and hand-manipulated current sensors intended for measuring, detecting or injecting current, or indicating current waveforms on circuits without physically opening the current path of the circuit being measured. These current sensors are hand-manipulated before and/or after a test or measurement, but are not necessarily hand-held during the test or measurement. They can be stand-alone current sensors or accessories to other equipment or parts of combined equipment. These include measurement circuits which are part of electrical test and measurement equipment, laboratory equipment, or process control equipment. This fifth edition cancels and replaces the fourth edition published in 2019. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) In 1.1.1, definitions of current sensor types have been moved to a new Annex FF; b) Clause 2, all normative references have been dated and new normative references have been added; c) 3.2.103, a new definition protective fingerguard has been added which replaces the previous definition of protective barrier; d) 4.4.2.101 is a new subclause about surge protective devices; e) in 5.1.5.101.2, minimum ratings for voltage of measuring terminals are required; f) Subclause 6.5.1 has been modified; g) Subclause 6.5.5 is no longer used; h) Subclause 6.6.101 modifies 6.6.101 and 6.6.102 of previous edition: 1) in 6.6.101.1, insulating material of group I may be allowed for determination of creepage distances of measuring circuit terminals; 2) in 6.6.101.2, clearances and creepage distances up to 3 000 V for measuring circuit terminals in unmated position have been defined; 3) in 6.6.101.3, requirements for measuring circuit terminals in partially mated position have been specified; 4) in 6.6.101.4, requirements for measuring circuit terminals in mated position have been specified; 5) Subclause 6.6.101.5 replaces 6.6.102; i) Subclause 6.6.102 replaces 6.101 of previous edition with modifications; j) Subclause 6.101.2 replaces 6.9.101.1 of previous edition with modifications; k) Subclause 6.101.3 replaces 6.9.101.2 of previous edition with modifications; l) Subclause 6.101.4 replaces 6.9.102 of previous edition with modifications; m) in 8.101, jaw ends abrasion test has been modified; n) 8.105 is a new subclause for input/output leads attachment has been added; o) in 9.101.2, relocation of 101.3 of previous edition; p) in 9.101.3, relocation of 101.4 of previous edition, extension to measurement category II and reference to IEC 61000-4-5 for tests: q) Table 104 has been replaced by Table K.101: r) in 9.102, relocation of Clause 102 of previous edition; s) in 14.101, relocation of 14.102. Subclause 14.101 of previous edition has been deleted; t) 101.3 is a new subclause for protections against hazard occurring from reading a voltage value in replacement of Clause EE.5 of previous edition; u) in Table D.101, transients are disregarded for insulation between jaw ends and input/output circuits; v) in Clause F.101, test voltages for routine test of jaws have been modified; w) in K.2.1, another method for determination of clearances of secondary circuits is proposed; x) in K.3.2, new Table K.15 and Table K.16 for clearance calculation; y) K.3.101 is a new clause; z) Clause K.4, redraft of the clause to propose a method for determination of Ut for circuits which reduce transient overvoltages; aa) Table K.101 replaces Table 104; bb) Subclause K.101.4 has been reviewed and tables and tests for solid insulation have been modified; cc) Table K.104 of previous edition has been deleted; dd) Annex AA: Figure AA.1 has been redesigned; ee) Annex EE: addition of a new informative annex for determination of clearances for Table 101; ff) Annex GG: this annex was Annex EE of previous edition and the current sensor type of a clamp multimeter is type A or type B. |
국제분류(ICS)코드 | 19.080 : 전기 및 전자 시험 및 측정기구 |
페이지수 | 152 |
Edition | 5.0 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 61010-2-032:2023상세보기 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2023-09-20 | 표준 |
2 | IEC 61010-2-032:2019/COR1:2020상세보기 | Corrigendum 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2020-02-26 | 구판 |
3 | IEC 61010-2-032:2019상세보기 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2019-06-21 | 구판 |
4 | IEC 61010-2-032:2019 RLV상세보기 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2019-06-21 | 구판 |
5 | IEC 61010-2-032:2012상세보기 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2012-09-26 | 구판 |
6 | IEC 61010-2-032:2002상세보기 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement | 2002-09-30 | 구판 |
7 | IEC 61010-2-032:1994상세보기 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test | 1994-12-15 | 구판 |
관련상품
- IEC 61010-2-031:1993 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-031: Particular requirements for hand-held probe assemblies for electrical measurement and test
- IEC 61010-2-041:1995 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-041: Particular requirements for autoclaves using steam for the treatment of medical materials, and for laboratory processes
- IEC 61010-2-043:1997 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-043: Particular requirements for dry heat sterilizers using either hot air or hot inert gas for the treatment of medical materials, and for laboratory processes
- IEC 61010-2-042:1997 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-042: Particular requirements for autoclaves and sterilizers using toxic gas for the treatment of medical materials, and for laboratory processes
- IEC TR 61010-3-010:1999 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-010: Conformity verification report for IEC 61010-2-010, Particular requirements for laboratory equipment for the heating of materials
다른 사람이 함께 구입한 상품
- IEC 61010-2-011:2019 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-011: Particular requirements for refrigerating equipment
- IEC 61010-2-020:2016 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-020: Particular requirements for laboratory centrifuges
- IEC 61010-2-061:2018 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization
- IEC 61010-031:2022 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
- IEC 61010-2-051:2018 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-051: Particular requirements for laboratory equipment for mixing and stirring
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)