해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
구판
판매
IEC 60079-14:2013
Explosive atmospheres - Part 14: Electrical installations design, selection and erection- 발행일 : 2013-11-28
- 발행기관 : IEC
- 대체표준 : IEC 60079-14:2024
상세정보
분야 | TC 31/SC 31J : Classification of hazardous areas and installation requirements |
---|---|
적용범위 | IEC 60079-14:2013 contains the specific requirements for the design, selection, erection and initial inspection of electrical installations in, or associated with, explosive atmospheres. Where the equipment is required to meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional protection requirements may be necessary. The requirements of this standard apply only to the use of equipment under standard atmospheric conditions as defined in IEC 60079-0. For other conditions, additional precautions may be necessary, and the equipment should be certified for these other conditions. For example, most flammable materials and many materials which are normally regarded as non-flammable might burn vigorously under conditions of oxygen enrichment. These requirements are in addition to the requirements for installations in non-hazardous areas. This standard applies to all electrical equipment including fixed, portable, transportable and personal, and installations, permanent or temporary. No account is taken in this Standard of the toxic risks that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower explosive limit. In locations where personnel may be exposed to potentially toxic concentrations of flammable material, appropriate precautions should be taken. Such precautions are outside the scope of this Standard. This fifth edition cancels and replaces the fourth edition published in 2007. This edition constitutes a technical revision. Refer to the document's Foreward for a listing of the specific revisions and additional Notes. Key words: requirements for the design, selection, erection and initial inspection of electrical installations in explosive atmospheres. The contents of the corrigendum of January 2016, the interpretation sheet 1 of February 2017 and March 2020 have been included in this copy. |
국제분류(ICS)코드 | 29.260.20 : 폭발 환경용 전기장치 |
페이지수 | 282 |
Edition | 5.0 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 60079-14:2024상세보기 | Explosive atmospheres - Part 14: Electrical installation design, selection and installation of equipment, including initial inspection | 2024-08-30 | 표준 |
2 | IEC 60079-14:2013/COR1:2016상세보기 | Corrigendum 1 - Explosive atmospheres - Part 14: Electrical installations design, selection and erection | 2016-01-28 | 구판 |
3 | IEC 60079-14:2013상세보기 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection | 2013-11-28 | 구판 |
4 | IEC 60079-14:2007상세보기 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection | 2007-12-13 | 구판 |
5 | IEC 60079-14:2002상세보기 | Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines) | 2002-10-24 | 구판 |
6 | IEC 60079-14:1996상세보기 | Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines) | 1996-12-10 | 구판 |
7 | IEC 60079-14:1984상세보기 | Electrical apparatus for explosive gas atmospheres. Part 14: Electrical installations in explosive gas atmospheres (other than mines). | 1984-01-01 | 구판 |
관련상품
- IEC 60079-8:1969 - Electrical apparatus for explosive gas atmospheres - Part 8: Classification of maximum surface temperatures
- IEC 60079-4A:1970 - Electrical apparatus for explosive gas atmospheres - Part 4: Method of test for ignition temperature - First supplement. *Note.-This supplement applies also to the second edition of 1975
- IEC 60079-9:1970 - Electrical apparatus for explosive gas atmospheres - Part 9: Marking
- IEC 60079-8:1969/AMD1:1972 - Amendment 1 - Electrical apparatus for explosive gas atmospheres - Part 8: Classification of maximum surface temperatures
- IEC 60079-4:1975 - Electrical apparatus for explosive gas atmospheres. Part 4: Method of test for ignition temperature
다른 사람이 함께 구입한 상품
- IEC 60079-19:2019 - Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation
- IEC 60079-14:2013/COR1:2016 - Corrigendum 1 - Explosive atmospheres - Part 14: Electrical installations design, selection and erection
- IEC 60079-17:2013 - Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
- IEC 60079-15:2017 - Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
- IEC 60079-0:2017 - Explosive atmospheres - Part 0: Equipment - General requirements
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)