QUICK

TOP

해외표준 상세정보

관심표준 등록 : 표준업데이트 시 알림서비스

제공형태 더보기
  • 표준

    판매

    IEC 60079-35-1:2011

    Explosive atmospheres - Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion
    • 발행일 : 2011-05-26
    • 발행기관 : IEC
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어/불어]PDF 199,900원

    • [영어/불어]PRINT 199,900원

상세정보

분야 TC 31 : Equipment for explosive atmospheres
적용범위 IEC 60079-35-1:2011 specifies requirements for the construction, testing and marking of caplights, including caplights with a point of connection for other equipment, for use in mines susceptible to firedamp (Group I - electrical equipment for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of the caplight becoming a source of ignition. The requirements for performance are in IEC 60079-35-2. This standard supplements and modifies the general requirements of IEC 60079-0 except as indicated in Table 1. This first edition cancels and replaces the second edition of IEC 62013-1, published in 2005, and constitutes a full technical revision. The main technical differences with respect to the previious edition are:
- the introduction of a means to achieve an equipment protection level (EPL) of Ma;
- the introduction of a single clause relating to equipment construction replacing individual specific clauses for the headpiece, battery, cable and external charging contacts;
- the deletion of statements relating to surface temperature, the rewording of statements relating to creepage and clearance and the addition of statements relating to thermal protection, electronic assemblies and additional circuitry;
- specific referenc to lithium cells;
- the addition of statements relating to battery recharging and protection against deep discharge.
국제분류(ICS)코드 29.260.20 : 폭발 환경용 전기장치
페이지수 38
Edition 1.0

이력정보

No. 표준번호 표준명 발행일 상태
1 IEC 60079-35-1:2011상세보기 Explosive atmospheres - Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion 2011-05-26 표준

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)