해외표준 상세정보
관심표준 등록 : 표준업데이트 시 알림서비스
제공형태 더보기-
표준
판매
IEC 60079-6:2015+AMD1:2020 CSV
Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"- 발행일 : 2020-02-24
- 발행기관 : IEC
상세정보
분야 | TC 31 : Equipment for explosive atmospheres |
---|---|
적용범위 | IEC 60079-6:2015+A1:2020 specifies the requirements for the design, construction, testing and marking of Ex Equipment and Ex Components with type of protection liquid immersion "o" intended for use in explosive gas atmospheres. Ex Equipment and Ex Components of type of protection liquid immersion "o" are either: - Level of Protection "ob" (EPL "Mb" or "Gb") or - Level of Protection "oc" (EPL "Gc"). For Level of Protection "ob", this standard applies where the rated voltage does not exceed 11 kV r.m.s. a.c. or d.c. For Level of Protection "oc", this standard applies where the rated voltage does not exceed 15 kV r.m.s. a.c. or d.c. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This fourth edition cancels and replaces the third edition, published in 2007. This edition constitutes a technical revision. The significant changes with respect to the previous edition are: - Edition 4 represents a major technical revision of the requirements for oil immersion "o" and should be considered as introducing all new requirements. The normal "Table of Significant Changes" has not been included for this reason. In particular: - The requirements for oil immersion "o" have been redefined into liquid immersion, levels of protection "ob" and "oc" as recommended by the responses to 31/715/DC; - The ability to protect sparking contacts has been added to both "ob" and "oc". Additional requirements have been introduced for the protective liquid. This consolidated version of the official IEC Standard and its amendment contains the fourth edition (2015) and its amendment 1 (2020). Therefore, no need to order amendments in addition to this publication. Keywords: Ex Equipment and Ex Components with type of protection liquid immersion "o" |
국제분류(ICS)코드 | 29.260.20 : 폭발 환경용 전기장치 |
페이지수 | 98 |
Edition | 4.1 |
이력정보
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 60079-6:2015/AMD1:2020상세보기 | Amendment 1 - Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" | 2020-02-24 | 표준 |
2 | IEC 60079-6:2015+AMD1:2020 CSV상세보기 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" | 2020-02-24 | 표준 |
3 | IEC 60079-6:2015상세보기 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" | 2015-02-20 | 표준 |
4 | IEC 60079-6:2007상세보기 | Explosive atmospheres - Part 6: Equipment protection by oil immersion "o" | 2007-03-13 | 구판 |
5 | IEC 60079-6:1995/COR1:2003상세보기 | Corrigendum 1 - Electrical apparatus for explosive gas atmospheres - Part 6: Oil-immersion "o" | 2003-09-22 | 구판 |
6 | IEC 60079-6:1995상세보기 | Electrical apparatus for explosive gas atmospheres - Part 6: Oil-immersion 'o' | 1995-04-28 | 구판 |
7 | IEC 60079-6:1968상세보기 | Electrical apparatus for explosive gas atmospheres - Part 6: Oil-immersed apparatus | 1968-01-01 | 구판 |
관련상품
- IEC 60079-8:1969 - Electrical apparatus for explosive gas atmospheres - Part 8: Classification of maximum surface temperatures
- IEC 60079-4A:1970 - Electrical apparatus for explosive gas atmospheres - Part 4: Method of test for ignition temperature - First supplement. *Note.-This supplement applies also to the second edition of 1975
- IEC 60079-9:1970 - Electrical apparatus for explosive gas atmospheres - Part 9: Marking
- IEC 60079-8:1969/AMD1:1972 - Amendment 1 - Electrical apparatus for explosive gas atmospheres - Part 8: Classification of maximum surface temperatures
- IEC 60079-4:1975 - Electrical apparatus for explosive gas atmospheres. Part 4: Method of test for ignition temperature
다른 사람이 함께 구입한 상품
- IEC 60079-7:2015+AMD1:2017 CSV - Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
- IEC 60079-14:2013 - Explosive atmospheres - Part 14: Electrical installations design, selection and erection
- IEC 60079-18:2014+AMD1:2017 CSV - Explosive atmospheres - Part 18: Equipment protection by encapsulation "m"
- IEC 60079-15:2017 - Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
- IEC 60079-13:2017 - Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
추천 상품
- IEC TS 63134:2020 - Active assisted living (AAL) use cases
- IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification
- KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs)
- KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs)
- KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스
제공형태 닫기
PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)보안PDF :
직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능PRINT :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)BOOK :
인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)ZIP :
압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)CD/DVD :
직접 파일 다운로드 및 인쇄(마이페이지 확인)DB :
별도 정보 제공HARDCOPY :
해외 배송 상품, 최대 3주 소요바인더 :
바인더 우편발송, 2~3일 소요온라인구독 :
WEB 접속 후 실시간 열람, 출력(1년간)